Cyanobacterial toxin biosensors for environmental monitoring and protection  

在线阅读下载全文

作  者:Paul Bertani Wu Lu 

机构地区:[1]Department of Electrical and Computer Engineering,The Ohio State University,Columbus,OH,43210,USA

出  处:《Medicine in Novel Technology and Devices》2021年第2期1-9,共9页医学中新技术与新装备(英文)

基  金:This work was supported by the Ohio Sea Grant[Grant Number:F2F000001];Ohio Department of Higher Education[Grant Numbers:GRT00050966,GRT00053491,GR119066];National Science Foundation[Grant Number:ECCS1809570].

摘  要:Cyanobacterial toxins are primarily monitored using a variety of commercially available techniques,such as enzyme-linked immunosorbent assay(ELISA)and liquid chromatography–mass spectrometry(LC-MS).Indeed,official protocols created and utilized by regulatory bodies have these methodologies ingrained into the technical documentation.However,biosensor technology has been advancing for decades and are positioned to replace many existing methods.The requirements of biosensors include,but are not limited to,real time diagnostics,ease of use(reducing requirements for trained personnel),lower costs,high sensitivity,robust platforms,and good reproducibility.In contrast,laboratory techniques like ELISA require immobile equipment and the use of certified standards for toxin quantification.The use of biosensors may reduce the overall burden of materials and associated costs of production.Given the regulatory limits for toxins in drinking water and recreation,a wide array of biosensor platforms(graphene-based,optical,immunological,etc.)reported in the literature have sufficient sensitivity to comply with these guidelines,however,currently no biosensor has been approved for use in the same manner or accepted as a suitable alternative.In many cases,biosensors have been compared in a limited capacity to established technologies such as the previously mentioned ELISA,LC-MS,and HPLC(High Performance Liquid Chromatography)and would serve as good tools to be used as proxy screening methods.Biosensors examined in this review are evaluated on four criterion:(1)feasibility for point-of-care(POC)use,(2)assay time(time from sample collection to receipt of data),(3)variation between measurements(reported coefficient of variation values),and(4)dynamic range and/or limit of detection(LOD)to obtain a measure of a given technique’s suitability to be used for toxin quantification and detection.

关 键 词:CYANOTOXIN BIOSENSOR Coefficient of variation Harmful algal blooms MICROCYSTIN Limit of detection 

分 类 号:TP2[自动化与计算机技术—检测技术与自动化装置]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象