出 处:《工程技术研究》2022年第14期170-172,共3页Engineering and Technological Research
摘 要:目前V型滤池由于过滤效果好、运行简单,在污水处理厂中得到了广泛的应用,但采用传统工艺过程中存在多种问题,需对V型滤池进行改良。文章以北京市某污水处理厂为研究案例,从设计参数、二次提升泵房、进水系统等方面深入探讨了V型滤池系统设计相关内容,并指出了设计过程中需注意的问题,提出了具体的优化措施,以供参考。At present, the V-type filter has been widely used in sewage treatment plants due to its good filtering effect and simple operation. However, there are many problems in the traditional process, and the V-type filter needs to be improved. Taking a sewage treatment plant in Beijing as the research case, this paper deeply discusses the design of V-type filter system from the aspects of design parameters, secondary lifting pump room, and water inlet system,and points out the problems needing attention in the design process, and puts forward specific optimization measures for reference.
分 类 号:X703[环境科学与工程—环境工程] TP273[自动化与计算机技术—检测技术与自动化装置]