600MW亚临界机组高压加热器失效分析及改造  被引量:1

Failure Analysis of the HP Heater used in the 600 MW Sub-critical Power Plant and Replacement of the Equipment

在线阅读下载全文

作  者:朱永葆 Zhu Yongbao(Hebei Datang International Wangtan Power Generation Co.,Ltd.,Tangshan 063610,Hebei,China)

机构地区:[1]河北大唐国际王滩发电有限责任公司,河北唐山063610

出  处:《电站辅机》2022年第3期28-32,共5页Power Station Auxiliary Equipment

摘  要:通过对某电厂1号机3号高压加热器自投产以来的U形管泄漏进行统计、分析,探讨引起换热U形管失效的种种因素,提出了高压加热器更换改造的方案。This paper mainly focus on the U-tube leakage of No.3 HP-heater of No.1 Unit in some power plant, which started to fail since its commissioning andnearly several times every year. Through the statistics and analysis of the failure data, we can discuss various factors leading to the failure of the tubes and point out the only solution to fix this problem is to replace the HP heater.

关 键 词:高压加热器 换热管泄漏 失效分析 更换改造 

分 类 号:TM621[电气工程—电力系统及自动化]

 