昌黎地震台地电场观测漏电干扰调查  被引量:1

Survey of leakage interference in the geoelectric field observation at Changli Seismic Station

在线阅读下载全文

作  者:周剑青[1] 郭建芳[2] 佟鑫[2] 张海博 朱彦珍 李宝群 王倩[2] ZHOU Jianqing;GUO Jianfang;TONG Xin;ZHANG Haibo;ZHU Yanzhen;LI Baoqun;WANG Qian(Chengde Seismic Station,Hebei Earthquake Agency,Hebei Province 067000,China;Tangshan Seismic Station,Hebei Earthquake Agency,Hebei Province 063021,China)

机构地区:[1]河北省地震局承德地震监测中心站,河北067000 [2]河北省地震局唐山地震监测中心站,河北063021

出  处:《地震地磁观测与研究》2022年第4期41-50,共10页Seismological and Geomagnetic Observation and Research

摘  要:2019年5月,昌黎地震台地电场观测连续多日出现漏电干扰,依据地球物理异常核实工作要求,从观测系统、自然环境、地球物理场、场地环境等方面进行了调查。在对多种因素逐一分析无果后,在测区附近做野外方向性实验重点排查,逐步缩小排查范围,最后发现在台站东偏南7°约3.78 km处,1家加工厂漏电作业,这导致地电场观测数据发生了畸变。In May 2019,there was continuous multi-day leakage interference in the geoelectric field observation of the Changli Seismic Station.According to the requirements of the precursory anomaly verification work,the staff conducts investigations from the observation system,natural environment,geophysical field,site environment,etc.After analyzing a variety of factors one by one to no avail,we focus on field directional investigations near the measurement area,and gradually narrow the scope of investigation.Finally,it was discovered that at a location of about 3.78 km 7°south east of the station,there was a leakage operation phenomenon in a factory,which caused distortion of the geoelectric field.

关 键 词:地电场 漏电干扰 实验排查 

分 类 号:P315.7[天文地球—地震学]

 