某循环流化床锅炉机组除尘器在役滤袋性能检测与分析  

Performance Analysis of the Filter Bags for Bag House in a Coal-fired Circulating Fluidized Bed Power Plant

在线阅读下载全文

作  者:熊冬 唐郭安 信晓颖 王东 Xiong Dong;Tang Guoan;Xin Xiaoying;Wang Dong(China Huadian Electric Research Institute Co.,Ltd.,Hangzhou 310000,China)

机构地区:[1]华电电力科学研究院有限公司,浙江杭州310000

出  处:《广东化工》2022年第20期261-263,共3页Guangdong Chemical Industry

摘  要:以某300 MW循环流化床锅炉机组电厂布袋除尘器在役滤袋为研究对象,对在役滤袋的性能进行了检测。通过滤袋工艺特性和理化特性检测结果发现,送检滤袋过滤效率仍能满足使用要求,但其经向断裂强力及透气性能均有明显下降,洁净滤料阻力及残余阻力显著升高,且现场运行环境恶劣,设备腐蚀严重,并有向糊袋发展迹象。结合现场实际运行状况,分析了滤袋阻力特性衰减的原因,为电厂组织开展脱硫除尘系统运行优化工作及滤袋更换工作提供了数据支持。In this study, the filter bag samples from a 300 MW coal-fired circulating fluidized power plant were tested. Through the results of process characteristics, morphological index, SEM, maximum force, air permeability and practical operating condition, the filter efficiency of the filter bag was still met operating requirement, but the maximum force and air permeability of the filter bag had been a significant decline, the differential pressure of the bag house rise obviously. The operating environment of system was bad and the facility of the bag house corroded seriously. This paper analyzed the factors that led to the reduction of the filter bag’s performance, and this work will provide data support for power plant to optimize the desulfuration and dust-collecting system operation and filter bag replacement schemes.

关 键 词:循环流化床 布袋除尘器 滤袋 糊袋 性能检测 

分 类 号:TQ[化学工程]

 