作 者:郭勇 王珏[3] 丁继峰 杨海洋 张波[1] 杨朝晖 李向阳 GUO Yong;WANG Jue;DING Ji-feng;YANG Hai-yang;ZHANG Bo;YANG Zhao-hui;LI Xiang-yang(Qingdao NCS Testing and Protection Technology Co.,Ltd.,Shandong Qingdao 266071,China;Central Iron and Steel Research Institute,Beijing 100081,China;Guangdong Dapeng LNG Co.,Ltd.,Guangdong Shenzhen 518048,China;Beijing Advanced Innovation Center for Materials Genome Engineering,China Iron&Steel Research Institute Group,Beijing 100081,China)
机构地区:[1]青岛钢研纳克检测防护技术有限公司,山东青岛266071 [2]钢铁研究总院,北京100081 [3]广东大鹏液化天然气有限公司,广东深圳518048 [4]中国钢研科技集团有限公司北京材料基因组工程先进创新中心,北京100081
出 处:《表面技术》2022年第10期235-242,共8页Surface Technology
基 金:国家自然科学基金项目(51771057)。
摘 要:目的针对埋地管道阴极保护测试用试片的失效问题进行原因分析,阐明了管道阴极保护测试用试片的失效现象及原因,为准确检测试片的阴极保护电位提供指导。方法以野外埋地管道相连接的试片为研究对象,采用数据记录仪采集试片的阴极保护参数,利用采集失效试片的通断电电位、交直流电流密度,干扰电压及试片表面腐蚀产物等来综合分析试片失效原因。结果试片表面宏观分析发现,试片表面腐蚀产物聚集,腐蚀产物和土壤夹杂在一起,形成坚硬的硬块,除去表面腐蚀产物后,试片表面有大小不均的腐蚀坑,最大坑深1 mm。试片表面腐蚀产物的元素面分析结果表明,锈层中的主要元素以Fe和O以元素为主,腐蚀产物以铁的氧化物为主,并夹杂有土壤杂质及钙镁难容盐等。试片历史数据显示,阴极保护电位满足规范要求,但交流电流密度较大,最大交流电流密度208.3 A/m^(2),最大交流干扰电压7.52 V。结合试片表面形貌,试片发生了交流腐蚀。结论阴极保护测试用试片的失效与交流腐蚀有关,试片在交流杂散电流和阴极保护电流的作用下,表面腐蚀产物聚集,难容盐与铁的氧化物形成厚厚的隔离层,隔离了试片与土壤介质,造成阴极保护电流流入困难,无法准确测量阴极保护电位。The work aims to analyze the cause of cathodic protection potential coupon of buried pipelines,so as to clarify the failure of the cathodic protection potential coupon of pipelines and corrosion mechanism,and put forward guidance for accurate detection and analysis of cathodic protection coupon instant-disconnect potential of buried pipelines.The cathodic protection potential coupons are more and more widely used under the interference of stray current,the coupons which connected to a buried pipeline in the field was used as the research object.A multifunction data recorder was used to record the cathodic protection parameters of the coupon.The reasons for the failure of the cathodic protection potential coupon are comprehensively analyzed by collecting the ON-potential,instant-OFF potential,DC current density,pipeline AC influence voltage,AC current density and detecting the components of the corrosion product on the surface of the coupon.The results of the macroscopic analysis showed that the corrosion products on the surface of the coupon had been corroded,and the corrosion products were mixed with the soil together,so that formed a hard and hard block.After the surface corrosion products were removed,the surface of the coupon had a number of uneven size corrosion pits,and the surface of the coupon was corroded and the maximum pit depth was 1mm.The element surface analysis results of the product show that the main elements in the rust layer are mainly Fe and O elements,and the corrosion products are mainly iron oxides,mixed with soil impurities and calcium and magnesium incompatible salts.The historical data of the cathodic protection potential coupon showed that the cathodic protection potential meet the specification requirements,but the AC current density was relatively high,the maximum AC current density was 208.3 A/m^(2),and the maximum AC interference voltage was 7.52 V.Combined with the surface morphology and the analysis of AC corrosion phenomena and conclusions made in the laboratory,the cathodic prot
分 类 号:TG172[金属学及工艺—金属表面处理]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.28