摘  要:苏州合景太湖新城商务中心地块一的裙房为7层商业,主楼为39层办公楼,主楼偏置于建筑平面北侧,结构平面在7层处有较大收进。主楼采用钢筋混凝土框架-核心筒结构体系,裙房部分采用框架-剪力墙结构体系,裙房与主楼采取不设缝方案。该项目为超限高层建筑,结构具有扭转不规则、塔楼偏置、局部穿层柱以及楼板不连续四项平面不规则项。根据结构不规则判别结果,针对抗震薄弱部位及关键构件选用适当的抗震性能目标,依据不同抗震性能目标采取一系列针对性抗震加强措施。采用SATWE对结构进行了小震弹性时程分析,并采用、MIDAS Building进行了小震弹性时程补充分析;采用SAUSAGE对结构进行大震弹塑性时程分析。结果表明,该项目的结构体系选择合理,具有良好的抗震性能,能够达到预定的抗震性能目标。The podium of plot 1 in Suzhou Hejing Taihu New Town Business Center is a 7-story commercial building,and the main building is a 39-story office building.The main building is located on the north side of the plane,and the structural plane has a larger shape retraction at the 7 th floor.The main building adopts reinforced concrete frame-core tube structure system,and the podium part adopts frame-shear wall structure system,and the podium and the main building adopt the scheme of no seam.The project is an out-of-code high-rise building,and the structure has four plane irregularities,namely,torsional irregularity,tower offset,local cross-layer column,and floor slab discontinuity.According to the results of structural irregularity discrimination,appropriate seismic performance targets were selected for the weak seismic parts and key components,and a series of targeted seismic strengthening measures were taken according to different seismic performance objectives.SATWE was used to conduct elastic time history analysis of the structure under small earthquake,and MIDAS Building was used to conduct elastic time history supplementary analysis of the structure under small earthquake.SAUSAGE was used to conduct elastic-plastic time history analysis of the structure under rare earthquake.The analysis results show that the structural system of the project is reasonably selected,has good seismic performance,and can achieve the predetermined seismic performance targets.

关 键 词:超高层结构 不设防震缝结构 抗震性能目标 抗震性能水准 抗震性能设计 体型收进 

分 类 号:TU318.2[建筑科学—结构工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象