检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:姚永良 黎乃斌 YAO Yongliang;LI Naibin(Guangdong Yuedian Dapu Power Generation Co.,Ltd.,Meizhou 514000)
机构地区:[1]广东粤电大埔发电有限公司,广东梅州514000
出 处:《电力安全技术》2022年第10期67-68,71,共3页Electric Safety Technology
摘 要:以某660 MW四角切圆燃烧锅炉的运行情况为例,对其在运行中水冷壁频繁超温、过热器出口两侧主蒸汽温度容易产生较大偏差的问题进行了详细的分析,并针对这一系列的问题重点对锅炉二次风的配风进行了优化,提高了锅炉的运行可靠性,为同类型锅炉燃烧调整的自动控制提供参考。Taking the operation of a 660 MW tangential firing boiler as an example,analyses are performed on the problems of frequent over-temperature of the water wall and large deviation of the main steam temperature on both sides of the superheater outlet during its operation.As for these problems,improvements are performed focused on optimizing the secondary air distribution of the boiler,which improves the operation reliability of the boiler and offers reference for the automatic control of combustion adjustment for the same type of boilers.
分 类 号:TM621.2[电气工程—电力系统及自动化]