检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:王杰[1] 陈林[1] 卫兵[1] 田青[1] 蒋吉昊[1] 赵越[1] 李逢[1] 周良骥[1] Wang Jie;Chen Lin;Wei Bing;Tian Qing;Jiang Jihao;Zhao Yue;Li Feng;Zhou Liangji(Key Laboratory of Pulsed Power,Institute of Fluid Physics,CAEP,P.O.Box 919-108,Mianyang 621999,China)
机构地区:[1]中国工程物理研究院流体物理研究所,中物院脉冲功率科学与技术重点实验室,四川绵阳621999
出 处:《强激光与粒子束》2022年第12期132-135,共4页High Power Laser and Particle Beams
摘 要:基于50级模块串联的LTD单路样机,开展了开关自放电故障耦合影响实验,获得了开路和短路负载下、不同位置LTD模块内单只开关自放电对其余LTD模块的电压耦合影响规律。结果表明,两种负载条件下,LTD模块内单只开关自放电时在其余模块内耦合的电压幅度均较低,且LTD距离越远电压幅度越低。在±83 kV的单只开关自放电电压下其相邻模块内耦合的最大电压幅度约2.43 kV(对应电压波动约3%)。The influences of switch prefire in different LTD cavities on the other cavities with shorted or open load have been researched based on the 50 stages linear transformer driver module.It is shown that the induced voltage in the other cavities is very low,and the amplitude of voltage signal will decrease with increase of distance.The maximal induced voltage is 2.43 kV when switch prefire occurred in neighbouring cavity at voltage of±83 kV.The results will contribute to reliability model constructing,analysis and assessment of large scale LTD generator.
关 键 词:直线变压驱动器 Z箍缩驱动器 气体开关 自放电故障
分 类 号:TM836[电气工程—高电压与绝缘技术]