检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:李旭岗 陈洁[1] 陈文魁 朱飞虎 朱亮亮 LI Xugang;CHEN Jie;CHEN Wenkui;ZHU Feihu;ZHU Liangliang(MOE Research Center of Renewable Energy Power Generation and Grid Connection Control Engineering Technology,School of Electrical Engineering,Xinjiang University,Urumqi 830017,China;Kezhou Power Supply Company,State Grid Xinjiang Electric Power Co.,Ltd.,Atux 844000,China)
机构地区:[1]新疆大学电气工程学院教育部可再生能源发电与并网控制工程技术研究中心,新疆乌鲁木齐830017 [2]国网新疆省电力有限公司克州供电公司,新疆阿图什844000
出 处:《现代电子技术》2022年第22期143-149,共7页Modern Electronics Technique
基 金:新疆维吾尔自治区自然科学基金项目(2019D01C78)。
摘 要:针对基于模块化多电平换流器的静止无功补偿器(MMC-STATCOM)所用子模块(submodule,SM)过多,导致系统复杂性上升等问题,文中提出一种双混合STATCOM,即在MMC-STATCOM基础上,用高耐压值GTO构成的H桥模块代替上桥臂,下桥臂采用半桥模块。首先对所提出的拓扑结构进行分析,并与其他方案的开关器件使用数量进行对比;然后提出针对该拓扑的载波移相、载波同相层叠两种调制方式,并考虑故障容错情况,形成两种三层电容电压均衡控制策略;最后在Simulink中搭建双混合STATCOM仿真模型对所提控制策略的有效性进行分析验证。结果表明:双混合STATCOM可明显降低开关器件使用数量;无故障时,两种控制策略下的双混合STATCOM均能稳定运行,保持良好的无功补偿能力;故障情况下,基于载波移相的控制策略具备更好的直流侧电容电压均衡能力。There are too many submodules(SM)used for modular multilevel converter STATCOM(MMC-STATCOM),which lead to the increase of system complexity,a dual-hybrid STATCOM is proposed,that is,on the basis of MMC-STATCOM,the H-bridge module composed of GTO with high withstand voltage is used to replace the upper bridge arm,and the half bridge module is used at the lower bridge arm.The proposed topology is analyzed and compared with the number of switching devices used in other schemes.Two modulation methods,carrier phase shift and carrier in-phase cascade,are proposed for the topology,the fault tolerance is considered,and two three-layer capacitor voltage balancing control strategies are formed.The simulation model of dual-hybrid STATCOM is built in Simulink to analyze and verify the effectiveness of the proposed control strategy.The results show that the dual-hybrid STATCOM can significantly reduce the number of switching devices.When there is no fault,the dual-hybrid STATCOM under the two control strategies can run stably and keep good reactive power compensation ability.In the case of fault,the control strategy based on carrier phase shift has better capability of capacitor voltage equalization on DC side.
关 键 词:模块化多电平换流器 静止无功发生器 碳化硅 中性点电压偏移 开关函数 载波移相 故障容错
分 类 号:TN761.7-34[电子电信—电路与系统] TM762[电气工程—电力系统及自动化]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:18.219.58.157