延长竖炉导风墙水梁寿命的措施  

Measures to Prolong the Service Life of Water Beam of Air Guide Wall of Shaft Furnace

在线阅读下载全文

作  者:王文明 杨新亚 Wang Wenming;Yang Xinya(Xinjiang Xin Hao Da Mining Limited Liability Company,Hami Xinjiang 839000)

机构地区:[1]新疆昕昊达矿业有限责任公司,新疆哈密839000

出  处:《山西冶金》2022年第6期89-90,111,共3页Shanxi Metallurgy

摘  要:昕昊达公司4台竖炉导风墙水梁采用了8根冷却水管加管壁外部堆焊设计,导风墙水梁设计及加工工艺存在一定的缺陷,严重制约了竖炉年修周期。目前竖炉年修周期为12~18个月。经过对导风墙水梁漏水原因进行分析,结合现场使用环境,重新对导风墙水梁结构进行改造,采用新的制作工艺进行加工,导风墙水梁使用寿命可延长至30个月以上。The water beam of air guide wall of four shaft furnaces in Xin Hao Da Company adopts 8 cooling water pipes and external surfacing welding design of pipe wall. The design andprocessing technology of the waterbeam of the air guide wall are defective. It seriously restricts the annual repair cycle of shaft furnace. At present, the annual repair cycle of shaft furnace varies from 12 to 16 months. The causes of water leakage of the water beam of the air guide wall are analyzed. The water beam structure of the air guide wall was reconstructed according to the site environment. The new production technology is adopted for processing. The service life of the water beam of the wind guide wall is extended to more than 30 months.

关 键 词:球团竖炉 导风墙水梁改造 均压腔 引流筋板 

分 类 号:TF554[冶金工程—钢铁冶金]

 