检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:张瑶瑶 张伟 李旭 ZHANG Yaoyao;ZHANG Wei;LI Xu(School of Energy and Safety Engineering,TCU,Tianjin 300384,China)
机构地区:[1]天津城建大学能源与安全工程学院,天津300384
出 处:《天津城建大学学报》2022年第5期331-335,共5页Journal of Tianjin Chengjian University
摘 要:根据火积耗散理论,建立了热管内气液二相介质的火积耗散率数学表达式,并将其编译成C语言程序嵌入到Fluent计算中,模拟分析并联分离式重力热管的传热特性.研究结果表明:热管传热过程中的不可逆损失主要由温差传热和相变两部分组成,在热管冷凝段,相变火积耗散数集中分布在热管顶端,约占冷凝段总火积耗散数的97.7%;此外,热管内总火积耗散数与加热功率呈正相关,随着加热功率的增加,热管内总体的不可逆程度增大.Based on the entransy dissipative theory,the entransy dissipative rate mathematical expression of gas-liquid two-phase medium in heat pipe is established,which is compiled into C language program and embedded into fluent calculation to simulate and analyze the heat transfer characteristics of parallel separated gravity heat pipe.The results show that the irreversible loss in the heat pipe is mainly composed of temperature difference heat transfer and phase change.In the condensation section of the heat pipe,the phase change entransy dissipation number is concentrated on the top of the heat pipe,accounting for 97.7%of the total entransy dissipation number in the condensation section.In addition,the total entransy dissipation number in the heat pipe is positively correlated with the heating power.With the increase of heating power,the overall irreversibility in the heat pipe increases.
分 类 号:TK172.4[动力工程及工程热物理—热能工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:18.221.139.13