检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:王娜 朱建敏 胡友森 张薇 陈天铭 WANG Na;ZHU Jianmin;HU Yousen;ZHANG Wei;CHEN Tianming(China Nuclear Power Technology Research Institute,Shenzhen of Guangdong Prov.518000,China)
出 处:《核科学与工程》2022年第5期1077-1084,共8页Nuclear Science and Engineering
摘 要:针对CPR1000直立式自然循环蒸汽发生器虚假水位现象进行研究,讨论了不同功率水平下的蒸汽发生器虚假水位现象,并进一步研究了水位控制方案对虚假水位的调节作用。结果表明,水位偏差与汽水失配串级控制方法对虚假水位现象具有良好的调节效果;在手动控制模式下,操纵员控制给水阀门应考虑到虚假水位的影响,以避免虚假水位现象触发报警信号甚至停堆保护信号。The false water level phenomenon of the vertical natural-circuit steam generator of CPR1000 has been investigated.The discussion on the false water level phenomenon under different power steps has been conducted,and based on which,several water level control methods have been discussed.The result shows that the cascade control of the water level deviation and steam-water mismatch has positive effect on the control of the false water level phenomenon.The operator should take the false water level into consideration when it comes to the manual control,in order to avoid triggering the alarm even the trip signal.
关 键 词:蒸汽发生器 虚假水位 CPR1000 CATIA2
分 类 号:TL48[核科学技术—核技术及应用]