检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:张腾 帅成光 Zhang Teng;Shuai Chengguang(Ebara Refrigeration Equipment&Systems(China)Co.,Ltd.)
机构地区:[1]荏原冷热系统(中国)有限公司
出 处:《制冷与空调》2022年第10期82-85,共4页Refrigeration and Air-Conditioning
摘 要:为提高冷水机组的部分负荷性能,满足用户的节能改造要求,本文对定频螺杆式冷水机组进行变频改造及相关试验研究。结果表明,定频螺杆式冷水机组变频改造后的综合部分负荷性能系数(IPLV)提高22%。最后对变频改造带来的运行电流、控制逻辑、运行范围、谐波、共振等问题给出相应解决方案。In order to improve the part load performance of the water chiller and meet the customer’s energy-saving transformation needs,a frequency conversion transformation of the fixed-frequency screw water chiller is carried out,and the relevant experimental research is done.The results show that the integrated part load value(IPLV)of the fixed-frequency screw water chiller after frequency conversion transformation increases by 22%.In addition,the solutions are given to the problems of running current,control logic,operating range,harmonics and resonance caused by the frequency conversion transformation.
正在载入数据...