硅胶支架装载技术在精密显微器械管理中的应用效果评价  被引量:1

Application effect of silica gel stent loading technology in precision microscopic instrument management

在线阅读下载全文

作  者:车凤莲[1] 陈维维 钱黎明[1] Che Fenglian;Chen Weiwei;Qian Liming(Sterilization Supply Center,Shanghai Jiao Tong University School of Medicine Affiliated Ruijin Hospital,Shanghai 200025,China;Wuxi Branch Hospital Sterilization Supply Center,Shanghai Jiao Tong University School of Medicine Affiliated Ruijin Hospital,Wuxi 214000,China)

机构地区:[1]上海交通大学医学院附属瑞金医院消毒供应中心,上海200025 [2]上海交通大学医学院附属瑞金医院无锡分院消毒供应中心,无锡214000

出  处:《中国实用护理杂志》2022年第26期2028-2032,共5页Chinese Journal of Practical Nursing

摘  要:目的改良精密显微器械的装载技术,达到既确保清洗及灭菌质量,又保证器械安全使用的目的。方法2021年1—3月将上海交通大学医学院附属瑞金医院80套精密显微器械按随机数字表法分为硅胶垫装载组(A组)和硅胶支架装载组(B组),每组各40套。比较2组器械的清洗效果,干燥效果,装载有效性,灭菌湿包情况,以及消毒供应中心工作人员对2组器械装载技术的操作满意度。结果A、B 2组器械的清洗合格数分别为37套、39套,2组比较差异无统计学意义(χ^(2)=1.05,P>0.05);干燥合格数A、B 2组分别为29套和38套,2组比较差异有统计学意义(χ^(2)=7.44,P<0.05)。装载有效数A、B 2组分别为30套和39套,2组比较差异有统计学意义(χ^(2)=8.54,P<0.05)。灭菌湿包数A、B 2组分别为6套和0套,2组比较差异有统计学意义(χ^(2)=6.49,P<0.05)。44名消毒供应中心人员对A、B 2组装载技术操作满意数分别为36人和43人,2组比较差异有统计学意义(χ^(2)=6.07,P<0.05)。结论采用硅胶支架装载精密显微器械,既能确保器械的清洗及灭菌质量,又可使器械装载更加安全稳妥,大大提高器械处理的工作效率,加快器械使用周转效率。Objective To improve the loading technology of precision micro instruments,so as to ensure not only the quality of cleaning and sterilization,but also the safe use of instruments.Methods From January to March,2021,80 sets of precision micro instruments from Sterilization Supply Center,Shanghai Jiao Tong University School of Medicine Affiliated Ruijin Hospital were randomly divided into silica gel pad loading group(group A)and silica gel stent loading group(group B),40 sets in each group.The cleaning effect,drying effect,loading effectiveness and sterilization wet bag of the instruments in the two groups were compared,and the staff of the disinfection supply center were satisfied with the operation of the loading technology of the instruments in the two groups.Results The qualified cleaning numbers of the instruments in group A and B were 37 and 39 respectively,and there was no significant difference between the two groups(χ^(2)=1.05,P>0.05).The qualified drying numbers in the group A and B were 29 and 38 respectively,the difference between the two groups was significant(χ^(2)=7.44,P<0.05).The effective number of loading in the group A and B were 30 cases and 39 cases respectively,the difference was significant between the two groups(χ^(2)=8.54,P<0.05).The number of sterilized wet bags in the group A and B were 6 cases and 0 cases respectively,the difference was significant between the two groups(χ^(2)=6.49,P<0.05).The satisfaction of 44 personnel in the disinfection supply center with the operation of loading technology were 36 and 43 respectively,the difference was statistically significant between the two groups(χ^(2)=6.07,P<0.05).Conclusion Loading precision micro instruments with silica gel stent can not only ensure the cleaning and sterilization quality of instruments,but also make the loading of instruments more safe and stable,greatly improve the working efficiency of instrument treatment and accelerate the turnover efficiency of instruments.

关 键 词:灭菌 精密显微器械 装载 清洗 

分 类 号:R472[医药卫生—护理学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象