栓钉锈蚀后钢-混凝土组合梁抗弯性能试验研究  被引量:4

Study on Bending Resistance of Steel-concrete Composite Beams after Stud Corrosion

在线阅读下载全文

作  者:曹国辉[1,2] 曹一青 周超 李海 CAO Guohui;CAO Yiqing;ZHOU Chao;LI Hai(School of Civil Engineering,Hunan City University,Yiyang 413000,China;School of Civil Engineering,Xiangtan University,Xiangtan 411100,China;School of Civil Engineering,Changsha University of Science&Technology,Changsha 410000,China)

机构地区:[1]湖南城市学院土木工程学院,湖南益阳413000 [2]湘潭大学土木工程学院,湖南湘潭411100 [3]长沙理工大学土木工程学院,湖南长沙410000

出  处:《铁道学报》2022年第11期129-135,共7页Journal of the China Railway Society

基  金:国家自然科学基金(52278174);湖南省自然科学基金(2021JJ50139)。

摘  要:对腐蚀与长期荷载耦合作用后的钢-混凝土组合梁进行了极限承载力试验,研究了栓钉锈蚀与长期荷载对组合梁极限承载力、跨中挠度、界面相对滑移的影响。研究结果表明,栓钉锈蚀后,组合梁跨中挠度和界面相对滑移增大,极限承载力降低。与未锈蚀试件相比,锈蚀试件极限承载力降低了0.5%~5.4%,160 kN荷载作用下的跨中挠度增加了8.2%~47.5%,120 kN荷载作用下最大界面相对滑移增加了34.6%~50.8%。与无长期荷载试件相比,有长期荷载试件极限承载力无明显降低,160 kN荷载作用下的跨中挠度增加了16.1%~19.0%,120 kN荷载作用下的最大界面相对滑移增加了18.3%~31.8%。考虑滑移效应的影响,提出栓钉锈蚀条件下钢-混凝土组合梁挠度计算方法,与试验结果比较,组合梁挠度理论值与实测值吻合较好,可为工程实际应用提供参考。In this paper,the ultimate bearing capacity tests of steel-concrete composite beams subjected to the coupling action of corrosion and long-term load were carried out,to study the effects of stud corrosion and long-term load on the ultimate bearing capacity,mid-span deflection,and relative slip at the steel-concrete interface,respectively.The results show that,after the corrosion of the studs,the mid-span deflection and the interface slip of composite beams increase,while their ultimate bearing capacity decreases.Specifically,compared with specimens without corroded studs,the ultimate bearing capacity of the ones with corroded studs drops by 0.5%to 5.4%,and their mid-span deflection with a load of 160 kN and maximum interface relative slip with a load of 120 kN increase by 8.2%to 47.5%and 34.6%to 50.8%,respectively.Compared with the specimens without the action of long-term load,the ultimate bearing capacity of the specimens under long-term loading does not decrease significantly,and their mid-span deflection with a load of 160 kN and the maximum interface relative slip with a load of 120 kN increase by 16.1%to 19.0%and 18.3%to 31.8%,respectively.Taking the influence of the interface slip into account,a calculation method for the deflection of steel-concrete composite beams with corroded studs was presented.The deflections obtained by this method agree well with the measured ones.Therefore,the proposed method can provide a valuable reference for practical engineering applications.

关 键 词:钢-混凝土组合梁 栓钉锈蚀 极限承载力试验 抗弯性能 挠度计算方法 

分 类 号:TU398.9[建筑科学—结构工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象