基于Pandora观测的OMI全球臭氧产品精度验证  

Accuracy verification of OMI global ozone products based on Pandora observations

在线阅读下载全文

作  者:汪可 李正强 李凯涛 许华 侯梦雨 王博林 WANG Ke;LI Zhengqiang;LI Kaitao;XU Hua;HOU Mengyu;WANG Bolin(College of Geography and Tourism Anhui Normal University,Wuhu 241003,China;Aerospace Information Research Institute,Chinese Academy of Sciences,Beijing 100101,China;Chinese Academy of Sciences University,Beijing 100049,China)

机构地区:[1]安徽师范大学地理与旅游学院,安徽芜湖241003 [2]中国科学院空天信息创新研究院,北京100101 [3]中国科学院大学,北京100049

出  处:《大气与环境光学学报》2022年第6期640-654,共15页Journal of Atmospheric and Environmental Optics

基  金:海南省重点研发科技合作方向项目,ZDYF2020206;国家杰出青年科学基金,41925019;国家自然科学基金,42175146。

摘  要:臭氧是大气中一种重要的微量气体,是影响对流层与平流层大气运动的重要成分之一,臭氧的高精度探测对于环境和气候具有重要的意义。OMI传感器是目前具备探测全球臭氧含量的主要遥感传感器之一。利用地基Pandora观测网全球范围内44个臭氧观测站点数据对OMI卫星数据产品进行了精度验证。结果表明:OMI臭氧产品与Pandora地基测量结果之间具有很好的线性相关性,相关系数达到0.948,但精度结果存在区域差异。在南半球地区,相关系数为0.915;在北半球低纬度地区,其相关系数为0.932,中纬度地区相关系数为0.948,而在高纬度地区,相关系数达到了0.957。此外,验证精度还与臭氧柱总量存在相关性,在臭氧柱总量低于220 Du(对应臭氧空洞条件)时,OMI卫星产品存在高估现象,高估约13%;而在臭氧柱总量高于400 Du时,OMI的臭氧产品低于Pandora地基测量结果,且随着臭氧柱总量增加,低估情况也越严重,在臭氧柱总量达到500 Du时,OMI臭氧产品低估约4%。As an important trace gas in the atmosphere,ozone is one of the important components that affect the movement of the atmosphere in the troposphere and stratosphere.The high-precision detection of ozone is of great significance to the environment and climate,and OMI sensor is currently one of the main remote sensing sensors capable of detecting global ozone levels.In this paper,the accuracy of OMI satellite data products is verified by using the data of 44 ozone observation stations around the world of the ground-based Pandora observation network.The results show that there is a good linear correlation between OMI ozone products and Pandora ground measurement results,with the correlation coefficient reaching 0.946.However,there are regional differences in the accuracy results.In the southern hemisphere,the correlation coefficient is 0.894.While in the northern hemisphere low latitudes,the correlation coefficient is 0.931,in the middle latitudes,the correlation coefficient is 0.951,and in the high latitudes,the correlation coefficient reaches 0.957.In addition,the verification accuracy is also related to the total ozone column.When the total ozone column is less than 220 Du(corresponding to the ozone hole condition),OMI satellite product is overestimated by about 13%.Above 400 Du,OMI′s ozone product is lower than Pandora′s ground-based measurement.And as the total ozone column increases,the underestimation becomes more serious.When the total ozone column reaches 500 Du,OMI′s ozone product is underestimated by about 4%.

关 键 词:地基验证 臭氧分布 相对误差 Pandora太阳光度计 

分 类 号:P407[天文地球—大气科学及气象学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象