Impact of window and air-conditioner operation behaviour on cooling load in high-rise residential buildings  被引量:1

在线阅读下载全文

作  者:Cong Yu Jia Du Wei Pan 

机构地区:[1]Department of Civil Engineering,The University of Hong Kong,Pokfulam,Hong Kong,China

出  处:《Building Simulation》2022年第11期1955-1975,共21页建筑模拟(英文)

基  金:supported by grants from the General Research Fund of the Hong Kong Research Grants Council[No.17203219];the Collaborative Research Fund of the Hong Kong Research Grants Council[No.C7047-20GF].

摘  要:Space cooling is an important building energy end-use that was found in recent years to be significantly impacted by occupant behaviours.However,the majority of previous studies ignored the interplay between the operation of windows and air conditioners(ACs)on cooling load,particularly in building energy modelling.In addition,studies on the analysis of cooling load characteristics regarding high-rise buildings are insufficient.The vertical effect of high-rise buildings on cooling load remains vague.This study thus aims to examine how window and AC operation behaviours impact the cooling load of high-rise buildings in an urban context demonstrated by a real-life typical 40-floor residential building in Hong Kong.This study investigates window and AC operation behaviours jointly and examines the vertical effect on cooling load by using agent-based building energy modelling(BEM)techniques and initiating stochastic and diverse behaviour modes.A carefully designed questionnaire survey was conducted to help build behaviour modes and validate energy models.Ninety building energy models were established integrating meteorological parameters generated by the computational fluid dynamics(CFD)programme for ten typical floors and nine combinations of window and AC behaviour modes.The results show that comfort-based AC modes and schedule-based window modes yielded the lowest cooling load.Considering the combined effect of AC and window uses,the maximum difference in cooling loads could be 26.8%.Behaviour modes and building height induce up to 32.4%differences in cooling loads.Besides,a deviation between the behaviour modes and height on the cooling load was found.The findings will help develop a thorough energy model inferring occupants’window and AC behaviour modes along with the building height in high-rise residential buildings.The findings indicate that the interaction impact of window and AC behaviour modes and height should be jointly considered in future high-rise building energy modelling,building energy standards,a

关 键 词:occupant behaviour air conditioning natural ventilation high-rise residential building building energy use 

分 类 号:TU241[建筑科学—建筑设计及理论]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象