检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:王平山 纵斌[1,2] 恽燕春 李进军 周颖[4] WANG Pingshan;ZONG Bin;YUN Yanchun;LI Jinjun;ZHOU Ying(East China Architectural Design and Research Institute Co.,Ltd.,Shanghai 200011,China;Shanghai Engineering Research Center of Assembly Building Technology Integration,Shanghai 200011,China;Baoye Group Co.,Ltd.,Shaoxing 312000,China;State Key Laboratory of Disaster Reduction in Civil Engineering,Tongji University,Shanghai 200092,China)
机构地区:[1]华东建筑设计研究院有限公司,上海200011 [2]上海装配式建筑技术集成工程技术研究中心,上海200011 [3]宝业集团股份有限公司,绍兴312000 [4]同济大学土木工程防灾国家重点实验室,上海200092
出 处:《建筑结构》2022年第23期7-13,125,共8页Building Structure
基 金:国家重点研发计划资助(2018YFD1100903)。
摘 要:在双面叠合剪力墙结构中集成夹心保温材料,设计形成适用于低层建筑的双面叠合夹心保温剪力墙结构,该结构具有构件生产和施工优势,具有应用推广前景。为研究该体系的抗震性能,对一栋两层两开间足尺模型进行地震振动台试验,分析结构在不同工况下的损伤累积过程,研究试验模型动力特性和地震响应的变化规律。试验表明,该结构在7度多遇、7度设防地震作用下基本保持完好,在7度罕遇、8度罕遇、9度罕遇地震作用下,试验模型自振频率出现一定下降,外观出现裂缝并随着地震作用的增强而不断发展,但结构没有明显的破坏现象,基本性能稳定。试验模型能够满足现行抗震规范三水准的设防要求,在低层建筑中具有一定的应用优势。Integrate the insulation material into the double-faced superimposed sandwich shear wall,a double-faced superimposed sandwich insulation shear wall structure suitable for low-rise buildings was designed.This structure has the advantages of component production and construction,and has application and promotion prospects.In order to study the seismic performance of the system,a full-scale two-story two-bay structure model was subjected to seismic shaking table test to analyze the damage accumulation process of the structure under different seismic conditions,and to study the dynamic characteristics of the text model and the change law of seismic response.Tests have shown that the structure remains basically intact under the action of 7-degree frequent and 7-degree fortified earthquakes.Under the action of 7-degree,8-degree,and 9-degree rare earthquakes,the natural frequency of the text model drops to a certain extent,and the appearance cracks appear and continue to develop with the increase of seismic action,but the structure has no obvious damage,and the basic performance is stable.The text model can meet the three-level fortification requirements of the current seismic code,and has certain application advantages in low-rise buildings.
关 键 词:装配式建筑 双面叠合夹心保温剪力墙 足尺结构振动台试验 抗震性能
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.28