GE控制系统(AC)接地保护原理与故障点快速诊断  

GE control system(AC)grounding protection principle and rapid diagnosis of fault points

在线阅读下载全文

作  者:庞松华 PANG Songhua(Halwusu Equipment Maintenance Center of National Energy Group Zhuneng Company,Ordos 010300,China)

机构地区:[1]国能集团准能公司哈尔乌素露天矿设备维修中心,内蒙古鄂尔多斯010300

出  处:《露天采矿技术》2022年第6期92-95,共4页Opencast Mining Technology

摘  要:为了快速判断和处理GE控制系统(AC)接地故障,分析了交流电动轮卡车接地保护电路的主要部件的作用及接地保护电路的工作原理,通过wPTU软件来对卡车实时运行数据进行数据分析,可以快速地判别接地故障的大概范围。结果表明:通过此处理方法可以大大地提高维修工作效率,避免了因盲目维修而造成的不必要损失。In order to quickly judge and deal with the ground fault of GE control system(AC),the article analyzes the function of the main components of the grounding protection circuit of the AC electric wheel truck and the working principle of the grounding protection circuit,and analyzes the real-time operation data of the truck by the wPTU software,and quickly determines the approximate range of the ground fault.The results show that this method can greatly improve the efficiency of maintenance work and avoid unnecessary losses caused by blind maintenance.

关 键 词:GE 交流电动轮卡车 wPTU软件 接地保护 接地故障 