直流电阻和绝缘电阻对变压器运行状态的影响及故障判断研究  被引量:8

Influence of DC Resistance and Insulation Resistance on Transformer Operation State and Fault Judgment

在线阅读下载全文

作  者:苏佳伟[1] 陈恳[1] SU Jiawei;CHEN Ken(Yunnan Normal University,Kunming 650500,China)

机构地区:[1]云南师范大学,云南昆明650500

出  处:《云南师范大学学报(自然科学版)》2022年第6期48-51,共4页Journal of Yunnan Normal University:Natural Sciences Edition

基  金:云南省教育后勤协会基金资助项目(YNJHYB2021014)。

摘  要:以在用10 kV变压器为测试对象,测量其直流电阻及绝缘电阻,研究其三相不平衡率,配合开展交流耐压试验,分析得到了测量对象的运行状态及潜在故障.Taking the 10 kV transformer in use as the test object, the DC resistance and insulation resistance were measured experimentally.The three-phase unbalance rate was studied, and the AC withstand voltage test was carried out in cooperation.The operation status and potential faults of the measured object were analyzed based on the experiment results.

关 键 词:直流电阻 三相不平衡率 绝缘电阻 交流耐压 

分 类 号:TM4[电气工程—电器]

 