机构地区:[1]广州中医药大学第三附属医院,广东广州510240 [2]湖北六七二中西医结合骨科医院,湖北武汉430079 [3]中国人民解放军总医院骨科,北京100853
出 处:《中国骨伤》2022年第11期1074-1080,共7页China Journal of Orthopaedics and Traumatology
摘 要:目的:分析单侧初次全髋关节置换使用Corail颈干角135°不同偏心距股骨假体的术后影像学参数,对比双侧测量结果,分析术后股骨偏心距的重建及髋关节功能恢复,探讨Corail标准柄KS型与高偏心距柄KHO型股骨假体在初次全髋关节置换中的早期临床疗效。方法:回顾性分析2015年1月至2017年6月使用强生Corail股骨柄假体行初次人工全髋关节置换186例单侧髋关节病变患者,根据术中使用不同偏心距股骨假体将患者分为高偏心距组和标准偏心距组。高偏心距组为Corail高偏心距假体KHO型52例,女20例,男32例;年龄21~71(50.6±13.2)岁;体质量指数(body mass index,BMI)(26.0±4.1)kg/m2。标准偏心距组为Corail标准股骨柄假体KS型134例,女57例,男77例;年龄18~77(47.3±14.0)岁;BMI(25.3±3.5)kg/m2。在术后髋关节正位X线片上测量外展力臂、股骨偏心距、髋臼偏心距、下肢长短差异,记录患者手术前后的Harris评分及相关并发症,分析假体的稳定性。结果:高偏心距组患侧与健侧股骨偏心距、联合偏心距、外展力臂差异有统计学意义(P<0.05)。标准偏心距组患侧与健侧股骨偏心距、髋臼偏心距差异有统计学意义(P<0.05)。两组患者联合偏心距、外展力臂、下肢长短差异有统计学意义(P<0.05)。高偏心距组患侧髋关节外展力臂与股骨偏心距、髋臼偏心距和联合偏心距呈正相关性(r=0.633,P<0.001;r=0.384,P=0.005;r=0.690,P<0.001),健侧也得到了同样的结果(r=0.688,P<0.001;r=0.574,P<0.001;r=0.765,P<0.001)。标准偏心距组患侧髋关节外展力臂与股骨偏心距、髋臼偏心距和联合偏心距呈正相关性(r=0.734,P<0.001;r=0.418,P<0.001;r=0.749,P<0.001),健侧也得到了同样的结果(r=0.775,P<0.001;r=0.397,P<0.001;r=0.773,P<0.001)。高偏心距组双下肢长短差异与双侧联合偏心距的差异、双侧外展力臂的差异均有明显相关性(r=0.376,P=0.006;r=-0.346,P=0.012)。标准偏心距组双下肢长短差�Objective:To explore the early clinical efficacy of primary total hip arthroplasty(THA) with Corail standard stems(KS type) and high offset stems(KHO type),by analyzing the postoperative radiographic parameters of different offset of femoral components with Corail stem which has a neck-shaft angle of 135° in unilateral primary THA,by comparing the measurement results on both sides and analyzing the reconstruction of the postoperative femoral offset and the hip joint function recovery.Methods:A retrospective analysis was made of 186 patients with unilateral hip joint lesions who underwent the first total hip arthroplasty with Johnson & Johnson Corail prostheses from January 2015 to June 2017.According to the use of femoral prostheses with different eccentricities during the operation,the patients were divided into high eccentricity group and standard eccentricity group.In the high eccentricity group,there were 52 cases of Corail high eccentricity prosthesis(KHO type) including 20 females and 32 males;aged 21 to 71 years old with an average of(50.6±13.2) years;body mass index(BMI) was(26.0±4.1) kg/m^2.The standard eccentricity group included 134 Corail standard femoral stem prostheses(KS type),57 females and 77 males;aged 18 to 77 years old with an average of(47.3±14.0) years;BMI was(25.3±3.5) kg/m^2.The abduction arm,femoral eccentricity,acetabular eccentricity and the length difference of lower limbs were measured on the postoperatively positive X-ray film of the hip joint.Harris score and related complications were recorded before and after the operation,and the stability of the prosthesis was analyzed.Results:There were significant differences in femoral eccentricity,joint eccentricity and abduction arm between the affected side and the healthy side in the high eccentricity group(P<0.05).There were significant differences in femoral eccentricity and acetabular eccentricity between the affected side and the healthy side in the standard eccentricity group(P<0.05).There were significant differences in combine
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...