GE6F.03燃气轮机一次调频测试逻辑优化  被引量:1

Logic Optimization of Primary Frequency Modulation Test for GE6F.03 Gas Turbine

在线阅读下载全文

作  者:肖新宇 胡尊民 于国强[1] 殳建军[1] 周帅 XIAO Xinyu;HU Zunmin;YU Guoqiang;SHU Jianjun;ZHOU Shuai(Jiangsu Frontier Electric Technology Co.,Ltd.,Nanjing 21102,China)

机构地区:[1]江苏方天电力技术有限公司,南京211102

出  处:《热力透平》2022年第4期295-298,共4页Thermal Turbine

摘  要:国内某GE6F.03燃气轮机联合循环机组的一次调频性能测试显示,其一次调频响应指数达不到电网要求。对一次调频测试逻辑进行了分析,根据其存在的不足,优化了一次调频测试逻辑。优化后的机组一次调频响应指数满足电网要求。研究成果可为GE6F.03燃气轮机一次调频测试逻辑优化提供参考。The primary frequency regulation performance test of a domestic GE6F.03 gas turbine combined cycle unit showed that its primary frequency regulation response index could not meet the requirements of the power grid.Analysis of the primary frequency modulation test logic was conducted,and the test logic was optimized according to its shortcomings.After the optimization,the primary frequency regulation response index of the unit could meet the requirements of the power grid.The research results can provide reference for the logic optimization of the primary frequency modulation test of GE6F.03 gas turbine.

关 键 词:一次调频测试 逻辑优化 响应指数 

分 类 号:TK472[动力工程及工程热物理—动力机械及工程]

 