检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:王曼丽[1] 李博[2] 张瑞瑞[1] 贾竹敏[3] 付留俊[1] 刘婕[1] 王巧丽 WANG Manli;LI Bo;ZHANG Ruirui(The First Afiliated Hospital of Henan University of Science and Technology,Luoyang 471003,Chinal)
机构地区:[1]河南科技大学第一附属医院内分泌科,洛阳471003 [2]河南科技大学第一附属医院眼科,洛阳471003 [3]河南科技大学第一附属医院健康管理科,洛阳471003 [4]中国人民解放军联勤保障部队第九八九医院神经外科
出 处:《中国糖尿病杂志》2022年第11期808-811,共4页Chinese Journal of Diabetes
基 金:2020年度河南省医学科技攻关计划项目(LHGJ20200593)。
摘 要:目的 探讨免散瞳眼底照相联合人工智能(AI)DR筛查系统在内分泌科的应用价值。方法 选取2018年3月至2021年1月于河南科技大学第一附属医院内分泌科住院并参与DR筛查的DM患者2281例(4471眼)的眼底照片,对比AI与内分泌科医生阅片诊断结果符合率。随机抽取542例(1000眼)患者眼底照片由眼科医生阅片,以眼科医生的判定结果为金标准,分析内分泌科和眼科医生阅片诊断结果的一致性及AI与眼科医生阅片诊断结果的一致性。结果 AI系统和内分泌科医生阅片有无DR的阳性符合率88.72%,阴性符合率为78.25%,总符合率为81.57%。内分泌科与眼科医生阅片有无DR结果的一致性Kappa值为0.910,敏感度为93.63%,特异度为97.16%。AI与眼科医生阅片有无DR结果的一致性Kappa值为0.882,敏感度为84.85%,特异度为98.21%。结论AI DR筛查系统阅片与内分泌科医生及眼科医生诊断结果的一致性较高,具有较高的敏感度和特异度,可用于DR筛查。Objective To explore the application value of non-mydriatic fundus photography combined with artificial intelligence(AI)diabetic retinopathy(DR)screening system in endocrinology department.Methods The fundus photos of 2281 patients(4471 cases)who were hospitalized in the Endocrinology Department of The First Affiliated Hospital of Henan University of Science and Technology from March 2018 to January 2021 and participated in DR screening were selected. The reading results from AI and endocrinologist were compared. The fundus photos of 542 patients(1000 cases)were randomly selected and read by ophthalmologists. Taking the judgment results of ophthalmologists as the gold standard,the diagnostic consistency between endocrinologists and ophthalmologists and AI were analyzed.Results Whether in patients with or without DR,the total coincidence rate of AI and endocrinologist was 81. 57%,with positive coincidence rate 88. 72% and the negative coincidence rate 78. 25%. The concordance Kappa value of endocrinologist and ophthalmologist was 0. 910,with the sensitivity 93. 63% and the specificity97. 16%. The concordance value of DR reading results between AI and ophthalmologist was 0. 882,with the sensitivity 84. 85% and the specificity 98. 21%.Conclusion The AI-DR screening system has a high diagnostic consistency with endocrinologists and ophthalmologists on DR screening.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.145