检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:梁浩 谢欢 王聪 秦川 张广韬 訾鹏 LIANG Hao;XIE Huan;WANG Cong;QIN Chuan;ZHANG Guangtao;ZI Peng(Electric Power Research Institute of State Grid Jibei Electric Power Co.,Ltd.,Beijing 100045,China;North China Branch of State Grid Corporation of China,Beijing 100010,China)
机构地区:[1]国网冀北电力有限公司电力科学研究院,北京市100045 [2]国家电网有限公司华北分部,北京市100010
出 处:《电力系统自动化》2022年第22期192-199,共8页Automation of Electric Power Systems
基 金:国家电网公司科技项目(5100-202114563A-0-5-SF)。
摘 要:加速功率型电力系统稳定器(PSS)在发电机深度调峰进相工况由于转速计算误差大导致功率低频振荡问题。文中结合现场功率振荡案例分析PSS产生负阻尼的原因。基于励磁装置采用电气量计算转速的主流方法,通过求解转速对有功和无功功率导数开展转速计算电抗参数灵敏度分析。研究在不同工况下电抗参数取值对转速计算误差影响。转速计算准确度与电抗参数以及机组运行工况相关,而且当电抗参数整定值偏大时,转速计算准确度随着机组有功降低、无功进相而变差。仿真测试和现场试验验证了理论分析的正确性,对转速计算所用电抗参数取值范围以及PSS试验注意事项提出指导建议。The problem of low-frequency power oscillation is caused by the large rotational speed calculation error of the powertype power system stabilizer(PSS) with improved rotational speed under the condition of deep peak regulation and leading phase of the generator. In this paper, the cause that PSS produces negative damping is analyzed based on the case of field power oscillation.Based on the mainstream method for calculating rotational speed by electrical quantities of excitation device, the sensitivity analysis of reactance parameters in rotational speed calculation is carried out by solving the derivative of rotational speed to active and reactive power. The influence of reactance parameters on rotational speed calculation error under different operation conditions is studied. The accuracy of rotational speed calculation is related to the reactance parameters and the operation conditions of the generator unit. When the reactance parameter setting value is too large, the accuracy of rotational speed calculation becomes worse with the reduction of the active power of the generator unit and the advance of reactive power. Simulation test and field test verify the correctness of the theoretical analysis, and provide guidance and suggestions on the range of reactance parameters used for the rotational speed calculation and the precautions for PSS test.
关 键 词:深度调峰 励磁装置 电力系统稳定器 低频振荡 电抗参数
分 类 号:TM712[电气工程—电力系统及自动化]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.21.186.117