基于深度调峰技术的600 MW火力发电机组性能试验分析  被引量:1

Performance Test Analysis of 600 MW Thermal Generating Unit Based on Deep Peak Regulating Technology

在线阅读下载全文

作  者:苏显贺 Su Xianhe(Datang Northeast Electric Power Test and Research Institute,Changchun 130102,China)

机构地区:[1]大唐东北电力试验研究院有限公司,吉林长春130102

出  处:《科学技术创新》2022年第36期47-50,共4页Scientific and Technological Innovation

摘  要:以某火力发电厂的600 MW空冷机组为例,在概述设备组成与参数的基础上,分别设计了一次风速测量与调平试验、燃烧调整试验和不投油最低稳燃负荷试验。试验结果表明,磨煤机一次风管的风速偏差<3%,烟气含氧量和排烟温度的偏差均符合相关标准,机组性能良好;不投油最低稳燃负荷为33.91%BMCR,满足规定的“不投油最低稳燃负荷<35%”的要求。根据试验结果,最终确定该机组的深度调峰负荷为37%ECR,可以保证调峰后机组的经济性、环保性、安全性达到最优。A 600 MW air-cooled unit in a thermal power plant is taken as an example. Based on the overview of equipment composition and parameters, a wind speed measurement and leveling test, a combustion adjustment test and a minimum steady combustion load test without oil injection are designed respectively. The test results show that the deviation of the wind speed of the primary duct of the coal mill is less than 3%,the deviation of the flue gas oxygen content and exhaust temperature are in line with the relevant standards,and the unit has good performance. The minimum stable combustion load without oil injection is 33.91% BMCR, which meets the requirement of "minimum stable combustion load without oil injection < 35%". According to the test results, the depth peak regulation load of the unit is finally determined to be 37% ECR, which can ensure the optimal economy, environmental protection and safety of the unit after peak regulation.

关 键 词:深度调峰技术 火力发电机组 一次风速 磨煤机 

分 类 号:TM621[电气工程—电力系统及自动化]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象