上海新国际博览中心隔离集中收治点应急改造弱电设计  

Emergency Reconstruction Intelligent Design of Isolation and Centralized Treatment Sites in Shanghai New International Expo Center

在线阅读下载全文

作  者:袁成翔 YUAN Chengxiang(Shanghai Architectural Design and Research Institute Co.,Ltd.,Shanghai 200041,China)

机构地区:[1]上海建筑设计研究院有限公司,上海200041

出  处:《现代建筑电气》2022年第12期25-28,47,共5页Modern Architecture Electric

摘  要:以上海新国际博览中心隔离集中收治点应急改造为例,介绍了此类应急改造项目安全区、限制区、污染区等不同区域弱电智能化及消防火灾自动报警设计的相关要点,并对应急改造项目智能化各系统设置优先级进行分析,可以为日后其他隔离集中收治点应急改造智能化系统设置原则提供参考。Taking the emergency reconstruction of the isolation and centralized treatment sites in Shanghai New International Expo Center as an example, this paper introduced the key points of intellectualization system and automatic fire alarm system design in different areas such as safety area, restricted area and pollution area of such emergency reconstruction projects.It analyzed the priority of the intelligent systems of the emergency reconstruction project, and then, it can provide reference for setting principles of intelligent system for emergency reconstruction of other isolated and centralized treatment sites in the future.

关 键 词:集中隔离收治点 应急改造 智能化系统 火灾自动报警系统 

分 类 号:TU852[建筑科学]

 