作 者:范磊[1,3] 魏越超[1,3] 郭宇 宫静芝[1,3] 史舒婷 刘素珍 FAN Lei;WEI Yue-chao;GUO Yu;GONG Jing-zhi;SHI Shu-ting;LIU Su-zhen(Taiyuan Earthquake Monitoring Center Station,Shanxi Earthquake Agency,Taiyuan,Shanxi 030025,China;Shanxi Earthquake Agency,Taiyuan,Shanxi 030021,China;National Continental Rift Valley Dynamics Observatory of Taiyuan,Taiyuan,Shanxi 030025,China)
机构地区:[1]山西省地震局太原地震监测中心站,山西太原030025 [2]山西省地震局,山西太原030021 [3]太原大陆裂谷动力学国家野外科学观测研究站,山西太原030025
出 处:《山西地震》2022年第4期9-12,37,共5页Earthquake Research in Shanxi
基 金:山西省地震局科研项目(SBK-2213、SBK-2120);山西太原大陆裂谷动力学国家野外科学观测研究站资助(NORSTY20-08、NORSTY20-11)。
摘 要:使用“中国地震前兆数据处理系统—地磁学科版”软件,将太原地震监测中心站的FHDZ-M15秒数据与多台站的地磁秒数据进行对比,量算出上临线等高压直流输电线路对太原站地磁数据的干扰幅度,进行相关性和误差分析。结果表明,高压直流输电对太原站地磁数据干扰幅度与台站至线路垂直距离成线性反比;F、H、D三分量干扰幅度与Z分量干扰幅度呈高度线性相关;以Z分量变化量为因变量,使用参考拟合公式,求取F、H、D的变化量,可用于地磁高压直流输电干扰的日常处理中。Using the software"China Seismic Precursor Data Processing System-Geomagnetism Subject Edition",the FHDZ-M15second data of Taiyuan Earthquake Monitoring Center Station is compared with those of many stations.The interference amplitude of HVDC transmission lines such as the upper and adjacent lines to the geomagnetic data of Taiyuan Seismic Station is measured,and the correlation and error analysis are also carried out.The results show that the interference amplitude of HVDC transmission to the geomagnetic data of Taiyuan Seismic Station is inversely proportional to the vertical distance between the station and the line.The interference amplitude of F,H,D components is highly linear with that of Z component.Taking the variation of Z component as the dependent variable and using the reference fitting formula,the variation of F,H,D can be obtained,which can be used in the daily processing of geomagnetic HVDC transmission interference.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.7