40MW灯泡贯流式机组水导轴承烧瓦事故分析及预防措施  被引量:1

Analysis and Preventive Measures for Water Guide Bearing Bush Burning Accident of 40MW Bulb Tubular Unit

在线阅读下载全文

作  者:李永强 LI Yong-qiang(Sichuan Energy Power Development Group Co.,Ltd.,Chengdu 610000,China)

机构地区:[1]四川能投电力开发集团有限公司,四川成都610000

出  处:《云南水力发电》2022年第12期236-239,共4页Yunnan Water Power

摘  要:以境外某水电站40MW灯泡贯流式机组为背景,以机组运行过程中发生的水导轴瓦烧损事故为例,介绍了电站水导轴承结构型式以及油系统在设计、运行管理中存在的问题和采取的改进措施,防范和避免水导轴承在运行过程再次出现烧瓦事故,保证电站机组的安全运行和管理。Taking a 40MW bulb tubular unit of a hydropower station abroad as the background, this paper introduces the structural type of the water guide bearing and the problems existing in the design, operation and management of the oil system of the hydropower station, as well as the improvement measures taken, taking the burning accident of the water guide bearing bush during the operation of the unit as an example. It can prevent and avoid the bushing burning accident of water guide bearing during operation, and ensure the safe operation and management of power plant units.

关 键 词:贯流式机组 油系统运行 水导轴瓦 防控措施 