提高自动准同期并网可靠性的研究与应用  被引量:1

Research and Application of Improving Reliability of Automatic Quasi-synchronization Grid Connection

在线阅读下载全文

作  者:李现启 LI Xian-qi(Yunnan Huadian Jinsha River Midstream Hydropower Development Co.,Ltd.,Liyuan Power Generation Branch,Lijiang 674122,China)

机构地区:[1]云南华电金沙江中游水电开发有限公司梨园发电分公司,云南丽江674122

出  处:《云南水力发电》2022年第12期263-266,共4页Yunnan Water Power

摘  要:电力系统中,同期点的断路器自动准同期并网是目前最常用的并网方式,稍有不慎将有可能造成非同期合闸或同期合闸不成功。通过对金沙江中游流域梨园水电站自动准同期并网方式进行分析研究,找出存在的不足,提出更优的并网解决方法,使自动准同期并网更可靠、稳定、快速。In power system, automatic quasi-synchronous grid connection of circuit breakers at the same time point is the most commonly used grid connection mode at present. If it is faulty, non-synchronous closing or synchronous closing may be unsuccessful. Through analysis and Research on automatic quasi-synchronization grid-connection mode of Liyuan Hydropower Station in the middle reaches of Jinsha River, the paper finds out the shortcomings and proposes better grid-connection solution to make the automatic quasi-synchronization grid-connection more reliable, stable and fast.

关 键 词:梨园水电站 自动准同期 断路器 可靠性 

分 类 号:TM561[电气工程—电器]

 