检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:李清泉 曲文韬 李相栋 傅炳南 殷丕盛 LI Qingquan;QU Wentao;LI Xiangdong;FU Bingnan;YIN Pisheng(State Grid Shandong Electric Ertrahigh Company,Jinan 250018,China;Guangzhou Goaland Enery Conservation Technology Co.,Ltd.,Guangzhou 510530,China)
机构地区:[1]国网山东省电力公司超高压公司,济南250018 [2]广州高澜节能技术股份有限公司,广州510530
出 处:《给水排水》2022年第12期95-100,共6页Water & Wastewater Engineering
摘 要:介绍了拉合尔换流站以深井水为水源的反渗透净化工艺。根据反渗透装置的运行情况和水质变化情况,确定了导致反渗透膜结垢的主要因素。通过化学方法确定了污染物成分,并提出了相应的解决措施。通过控制加药量、加药逻辑以及低压水冲洗逻辑,有效控制了反渗透膜的结垢速度,改善了阀冷水处理系统的运行工况。The reverse osmosis purification process with deep well water as water source in Lahore converter station is introduced.According to the operation of the reverse osmosis device and the change of water quality,the main factors leading to the scaling of the reverse osmosis membrane are determined.The composition of pollutants was determined by chemical methods,and the corresponding solutions were put forward.By controlling the dosage,dosing logic and low-pressure water flushing logic,the scaling speed of reverse osmosis membrane is effectively controlled and the operation condition of valve cold water treatment system is improved.
关 键 词:反渗透 结垢 逻辑控制 深井水水源 阀冷水处理系统
分 类 号:X703[环境科学与工程—环境工程]