作 者:张继龙 纪建臣 骆无瑕 刘勇[2] 王岚 武朝辉 黎春 高雪梅 韩叶良 ZHANG Ji-long;JI Jian-chen;LUO Wu-xia;LIU Yong;WANG Lan;WU Zhao-hui;LI Chun;GAO Xue-mei;HAN Ye-liang(State Nuclear Security Technology Center,Beijing 102401,China;Nuclear Power Institute of China,Chengdu 610213,China)
机构地区:[1]国家核安保技术中心,北京102401 [2]中国核动力研究设计院,四川成都610213
出 处:《质谱学报》2023年第1期105-112,共8页Journal of Chinese Mass Spectrometry Society
摘 要:全蒸发热表面电离质谱(TE-TIMS)是测定铀主同位素比(^(235)U/^(238)U)最经典的方法,但受限于强峰拖尾等因素影响,次同位素比(^(234)U/^(238)U、^(236)U/^(238)U)的测量精密度不高,存在偏差。本工作研究目标动态加热程序、动态和静态相结合的接收程序、强峰拖尾校正、不同接收器效率校正、质量歧视校正等,建立了改良全蒸发-热表面电离质谱技术(MTE-TIMS)高精度测定铀同位素比的方法,通过测试标准物质验证方法的准确性和可靠性。结果表明:采用MTE-TIMS法测量^(235)U丰度为2%的铀样品,其^(235)U/^(238)U、^(234)U/^(238)U和^(236)U/^(238)U的方法精密度分别为0.024%、0.06%和0.19%,测量值与参考值的偏差分别为0.025%、0.19%和0.38%。Thermal ionization mass spectrometry(TIMS)is a well-established instrumental technique for accurately analyzing isotopes of elements with low first ionization potential.However,the measurement accuracy is affected due to the existence of the mass fractionation effect.Generally,applying the external standard method or total evaporation method is the most common way to correct the mass fractionation effect.Total evaporation(TE)technology is the most conventional method for uranium major isotope ratio measurement(^(235)U/^(238)U)using TIMS.However,due to the strong peak tailing of the major isotopes and other factors,the measurement precision and accuracy of minor isotope ratios(^(234)U/^(238)U and^(236)U/^(238)U)are relatively low.In this study,the modified total evaporation(MTE)method for highly precise measurement of uranium isotopes ratios by TIMS was developed based on the research of dynamic heating procedures,dynamic and static receiving procedures,peak tailing correction,efficiency calibration of collectors and mass discrimination calibration.The accuracy and reliability of the MTE method were verified with different reference materials.The experiment results showed that the yield of uranium oxide should be monitored and the related parameters should be precisely controlled to reduce the yield of uranium oxidation during measurement.This action could guarantee the effectiveness of the MTE measurement and improve the uranium samples utilization.The initial strength of ^(187)Re^(+) played an important role in the ionization efficiency of uranium and the yield of uranium oxide.The optimal signal of ^(187)Re^(+) should be set in the range of 0.17-0.22 V.When uranium samples with 2%235 U isotopic abundance were measured by the MTE method using TIMS,the measurement precisions of ^(235)U/^(238)U,^(234)U/^(238)U and^(236)U/^(238)U were 0.024%,0.06%,and 0.19%,and the bias between the measured value and reference value were 0.025%,0.19%,and 0.38%,respectively.Compared to the TE method,the MTE method showed the same pr
关 键 词:改良全蒸发(MTE) 铀同位素 动态法 热表面电离质谱(TIMS) 全蒸发(TE)
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:18.218.232.140