基于XMPP的分布式电源监控系统通信应用  被引量:5

XMPP-Based Communication Application for Distributed Power Monitoring Systems

在线阅读下载全文

作  者:欧阳卫年 赵瑞锋 卢建刚 黎皓彬 OUYANG Weinian;ZHAO Ruifeng;LU Jiangang;LI Haobin(Foshan Power Supply Bureau,Guangdong Power Grid Co.,Ltd.,Foshan 528322,China;Electric Dispatch and Control Center,Guangdong Power Grid Co.,Ltd.,Guangzhou 510062,China)

机构地区:[1]广东电网有限责任公司佛山供电局,广东佛山528322 [2]广东电网有限责任公司电力调度控制中心,广东广州510062

出  处:《自动化仪表》2023年第1期66-71,共6页Process Automation Instrumentation

基  金:中国南方电网有限责任公司科技基金资助项目(030600KK52190184 GDKJXM20198132)。

摘  要:为实现虚拟电厂(VPP)对不同权属的分布式电源(DER)的有效监控,需要解决监控系统的互联互通和通信安全问题。基于IEC 61850标准,研究了DER监控终端的信息模型和通信映射方法。以DER监控的信息交互需求和功能为基础,基于IEC 61850-7-420标准定义的逻辑节点建立了DER监控终端信息模型。针对DER监控系统应用通信架构服务需求,基于可拓展通信和表示协议(XMPP)通信映射机制实现了DER监控终端的信息模型和数据的规范传输。XMPP内置的传输层安全(TLS)协议和简单的身份验证安全层(SASL)协议通过通道安全加密、认证机制、数据完整性和保密安全服务保证信息传输的安全。搭建试验平台,以测试XMPP映射的传输性能。测试结果表明,XMPP的实时性可满足DER监控系统的安全通信要求。To achieve effective monitoring of distributed energy resources(DER) with different ownership in virtual power plant(VPP), the interconnection and communication security of monitoring systems need to be addressed. Based on the IEC 61850 standard, the information model and communication mapping method of DER monitoring terminals are studied. Based on the information interaction requirements and functions of DER monitoring, the information model of DER monitoring terminals is established based on the logical nodes defined in the IEC 61850-7-420 standard. The information model and the standardized data transmission of DER monitoring terminals are realized based on the extensible message and precence protocol(XMPP) communication mapping mechanism for the application communication architecture service requirements of DER monitoring systems. XMPP’s built-in transport layer security(TLS) protoul and simple authentication security layer(SASL) protocol ensure the security of information transmission through chammel security entryption, authentication mechanison, data integrity and confidential security services.A testbed is built to test the transmission performance of the XMPP mapping, and the test results showed that the real-time performance of XMPP can meet the secure communication requirements of DER monitoring systems.

关 键 词:分布式电源监控 虚拟电厂 IEC 61850-7-420 信息建模 服务映射 可拓展通信和表示协议 通信安全 实时性 

分 类 号:TH-183[机械工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象