循环冷却水浓缩倍率对循环水系统影响的研究  被引量:3

Study on High Cycle of Concentration of Recirculating Cooling Water Test

在线阅读下载全文

作  者:毕国旗 BI Guoqi(Datang Changshan Co-generation Power Plant,Songyuan 131109,China)

机构地区:[1]大唐长山热电厂,吉林松原131109

出  处:《吉林电力》2022年第6期46-48,共3页Jilin Electric Power

摘  要:为了提高水资源利用率,通过极限碳酸盐硬度试验、动态循环模拟试验,确定机组循环水系统最优运行工艺参数:阻垢剂加药量为2.5 mg/L时浓缩倍率控制为4.5~5.5,Cl^(-)含量为184.51~196.92 mg/L,全碱度为2.71~3.52 mmol/L,pH为8.30~8.51,CODCr为28.36~40.25 mg/L,总磷(以P计)含量为0.60~0.85 mg/L。在此运行条件下,循环水系统无结垢腐蚀倾向,污垢热阻小于标准要求值。In order to improve the utilization rate of water resources,through the limit carbonate hardness test and dynamic cycle simulation test,the optimal operation parameters of open circulating water system of a power plant were identified:when dosage of antisludging agent was 2.5 mg/L,cycle of Concentration is 4.5~5.5,Cl^(-)content is 184.51~196.92 mg/L,total alkalinity is 2.71~3.52 mmol/L,pH is 8.30~8.51,CODCris 28.36~40.25 mg/L total phosphorus(P)is 0.60~0.85 mg/L.Circulating water system had no scaling tendency under this operating condition,and the fouling thermal resistance was less than the standard value.

关 键 词:循环冷却水 极限碳酸盐硬度试验 浓缩倍率 

分 类 号:TM62[电气工程—电力系统及自动化]

 