摘  要:针对低温高湿环境工况下换流站阀厅湿度高且无法调节的问题,研究了换流站阀厅环境湿度控制原理,分析了不同阀厅空调参数工况下对阀厅环境湿度的控制效果,提出阀厅空调环境湿度控制策略的优化策略,并提出运维建议。Aiming at the problem that the humidity of the valve hall of the converter station is high and cannot be adjusted under the working conditions of low temperature and high humidity environment,the principle of ambient humidity control of the valve hall of the converter station is studied,and the control effect of the ambient humidity of the valve hall under the air conditioning parameters of different valve halls is analyzed.The optimization strategy of the ambient humidity control strategy of the valve hall air conditioner is proposed,and the operation and maintenance suggestions are put forward.

关 键 词:换流站 阀厅空调 湿度控制 

分 类 号:TM46[电气工程—电器]

 