桃源水电站运行水头超设计范围的对策研究  被引量:2

Study on Countermeasures of Operating Head exceeding Design Range of Taoyuan Hydropower Station

在线阅读下载全文

作  者:杨斌 贾函 楼正赞 孙方剑 YANG Bin;JIA Han;LOU Zhengzan;SUN Fangjian(Sinohydro Taoyuan Development Co.,Ltd.,Taoyuan 415700,Hunan,China;PowerChina Zhongnan Engineering Corporation Limited,Changsha 410014,Hunan,China)

机构地区:[1]中国水电顾问集团桃源开发有限公司,湖南桃源415700 [2]中国电建集团中南勘测设计研究院有限公司,湖南长沙410014

出  处:《水力发电》2023年第2期88-90,共3页Water Power

摘  要:灯泡贯流式机组在我国低水头电站中运用广泛,因其结构复杂,超设计水头范围运行存在较大安全隐患。近年来,受下游挖沙、航道整治等河势演变影响,沅江、湘江、赣江部分低水头电站水头超高现象频发,严重影响机组运行安全及梯级效益发挥。以沅水桃源水电站为例,通过问题剖析、对策分析、方案比选、影响评价等步骤探索解决该类问题的技术路径。The bulb turbine is widely used in low-head hydropower stations in China.Due to their complex structure,there are great security risks in the operation beyond the design head range.In recent years,affected by the evolution of river bed such as downstream sand dredging and waterway improvement,some low-head hydropower stations on the Yuanjiang,Xiangjiang and Ganjiang rivers have experienced excessively high head in power generation,which seriously affects the safety of unit operation and the performance of cascade benefits.Taking Taoyuan Hydropower Station on Yuanshui River as an example,the technical path to solve such problems is explored through the steps of problem analysis,countermeasure analysis,scheme comparison,and impact assessment.

关 键 词:低水头电站 灯泡贯流式机组 超设计水头运行 安全 优化调度 桃源水电站 

分 类 号:TM312[电气工程—电机]

 