汽轮机组提高一次调频能力的优化研究  被引量:2

Optimization Research on Improving Primary Frequency Modulation Capability of Steam Turbine Unit

在线阅读下载全文

作  者:蒋晓锋 王勇 陶丽 施鸿飞 朱晓磊 雷承勇 曹建文 JIANG Xiao-feng;WANG Yong;TAO Li;SHI Hong-fei;ZHU Xiao-lei;LEI Cheng-yong;CAO Jian-wen(Shanghai Power Equipment Research Institute Co.,Ltd.,Shanghai 200240,China)

机构地区:[1]上海发电设备成套设计研究院有限责任公司,上海200240

出  处:《汽轮机技术》2022年第6期465-468,共4页Turbine Technology

摘  要:鉴于常规一次调频方式对机组经济性的影响,以660MW超超临界汽轮机组为分析对象,从抽汽侧和给水侧提出一次调频优化手段。研究表明,采用蒸汽侧或给水侧一次调频时给水温度大幅降低,采用蒸汽侧一次调频会引起高加的工作压力变化。通过对比,推荐采用给水调频旁路来提升机组一次调频能力。In view of the impact of conventional primary frequency modulation on unit economy,the optimization method of primary frequency modulation was proposed from the steam side and the feed side,taking the 660MW ultra-supercritical steam turbine unit as the analysis object.The results show that the feed water temperature decreases greatly when the steam side or the feed water side primary frequency modulation is adopted,and the steam side primary frequency modulation will cause the change of high working pressure.By comparison,it is recommended to adopt the feed water frequency modulation bypass to improve the primary frequency modulation capacity of the unit.

关 键 词:一次调频 抽汽侧和给水侧 给水调频旁路 

分 类 号:TM621[电气工程—电力系统及自动化]

 