作 者:张建鸣 李志伟 刘芳 李景太 冒鑫 程雅苹 庞捷 冯鑫茁 倪四道 欧阳晓平[4] 韩然[2] Zhang Jian-Ming;Li Zhi-Wei;Liu Fang;Li Jing-Tai;Mao Xin;Cheng Ya-Ping;Pang Jie;Feng Xin-Zhuo;Ni Si-Dao;Ouyang Xiao-Ping;Han Ran(College of Nuclear Science and Engineering,North China Electric Power University,Beijing 102206,China;Key Laboratory of Reliability and Environmental Engineering,Beijing Institute of Spacecraft Environment Engineering,Beijing 100094,China;Key Laboratory of Geodesy and Geodynamics,Academy of Precision Measurement Science and Technology Innovation,Chinese Academy of Sciences,Wuhan 430077,China;Northwest Institute of Nuclear Technology,Xi’an 710024,China)
机构地区:[1]华北电力大学核科学与工程学院,北京102206 [2]北京卫星环境工程研究所,可靠性与环境工程重点实验室,北京100094 [3]中国科学院精密测量科学与技术创新研究院,大地测量与地球动力学国家重点实验室,武汉430077 [4]西北核技术研究所,西安710024
出 处:《物理学报》2023年第2期35-44,共10页Acta Physica Sinica
基 金:国家自然科学基金(批准号:42174076,41974064)资助的课题.
摘 要:缪子透射成像方法是一种基于宇宙线缪子穿过目标物体前后的通量变化,进而获得其内部密度结构的无损探测成像方法.缪子透射成像方法假设缪子在低原子序数物质中沿直线运动,但实际上多重库仑散射作用会使缪子路径一定程度上偏离直线,有可能对成像精度造成影响.为此,本文使用Geant4软件包开展了缪子透射成像蒙特卡罗模拟,针对数米尺度多种密度结构的模型,定量分析了打开和关闭多重库仑散射物理过程时对成像精度的影响.结果表明:对于数米尺度标准岩石物质,缪子透射成像方法能够很好地恢复内部密度异常几何特征;但多重库仑散射作用对目标物体内部区域近垂向缪子通量造成的偏差可达5%,而在目标物体边界区域的偏差可达13%.因此,需要宇宙线缪子透射成像中考虑多重库仑散射作用的影响,以获得数米尺度目标物体更准确的绝对密度值成像结果.The muon transmission imaging method is a non-destructive detection imaging method and can obtain the internal density structure of the target object by analyzing the flux change of cosmic ray muon before and after passing through the target object.This method assumes that muon travels along a straight line in a lowatomic number material.However,the multiple Coulomb scattering causes the muon deviate from the straight line to a certain extent when penetrating the material,which may have a certain influence on the accuracy of muon transmission imaging.This study uses the Geant4 software package to carry out Monte Carlo simulation of muon transmission imaging.Object models with multiple density structures and several meters are used to analyze the effect of multiple scattering on the accuracy of transmission imaging.In the experiment,we set up a model in which muons of different energy vertically pass through a rock with a certain thickness,we can intuitively see the influence of scattering on the penetration path of muons.By setting up rock-water block models with thickness in a range of 0.8,2.4 and 4.0 m,the effect of Coulomb scattering on the transmission imaging of small-scale material muons is analyzed.The results suggest that the muon transmission imaging method can well restore the geometric shape and spatial distribution characteristics of density anomalies for objects with several-meter scale for standard rock materials with a scale of several meters.However,the flux deviation caused by multiple Coulomb scattering on the muons in the near-vertical direction can reach 5%,and up to 13%in the boundary areas of the standard rock and air.We limit the scattering angle of the muon,and select the muon with a scattering angle of less than or equal to 1°for imaging.The results of transmission imaging by using the selected muon have improved.The image does not have the illusion of an abnormally increased flux around the model caused by scattering,but the muon flux in the model area is reduced even more,thereby affec
关 键 词:多重库仑散射 宇宙线缪子 密度结构 成像精度 透射成像
分 类 号:O572.323[理学—粒子物理与原子核物理]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.222