余热发电锅炉水汽质量检验及爆管事故浅析  被引量:1

Water Vapor Quality Inspection and Pipe Explosion Accident Analysis of Waste Heat Power Generation Boiler

在线阅读下载全文

作  者:刘一杰 LIU Yi-Jie(Fujian Boiler and Pressure Vessel Inspection Institute,Fuzhou 350008,Fujian,China;National Industrial Boilers Quality Supervision and Inspection Center(Fujian),Fuzhou 350008,Fujian,China)

机构地区:[1]福建省锅炉压力容器检验研究院,福建福州350008 [2]国家工业锅炉质量监督检验中心(福建),福建福州350008

出  处:《市场监管与质量技术研究》2022年第6期6-8,13,共4页Market Regulation and Quality Technology Research

摘  要:文中通过对某余热发电锅炉的水汽质量检验与割管垢样化验,分析一起由于结垢造成的锅炉过热器爆管事故,并给出整改措施和建议,阐述锅炉水汽质量检验定期检验的重要性。Based on the water vapor quality inspection and pipe cutting scale sample test of a waste heat power generation boiler,this paper analyzes a boiler superheater tube explosion accident caused by scaling,putting forward measures and suggestions for rectification,and expounds the importance of periodic inspection of boiler water vapor quality inspection.

关 键 词:余热发电锅炉 结垢 爆管 水汽质量检验 割管垢样 整改措施 重要性 

分 类 号:TM617[电气工程—电力系统及自动化]

 