风电场群无功不均衡/无功环流抑制研究  被引量:3

Reactive Power Unbalance/Circulation Suppression for Wind Farm Group

在线阅读下载全文

作  者:郭嘉庆 乔颖[1] 鲁宗相[1] 徐曼 李佳明 GUO Jiaqing;QIAO Ying;LU Zongxiang;XU Man;LI Jiaming(State Key Lab of Control and Simulation of Power Systems and Generation Equipment(Dept.of Electrical Engineering,Tsinghua University),Haidian District,Beijing 100084,China;State Grid Jibei Electric Power Research Institute(North China Electric Power Research Institute Co.,Ltd.),Xicheng District,Beijing 100045,China)

机构地区:[1]电力系统及发电设备控制和仿真国家重点实验室(清华大学电机系),北京市海淀区100084 [2]国网冀北电力有限公司电力科学研究院(华北电力科学研究院有限责任公司),北京市西城区100045

出  处:《电网技术》2023年第1期109-119,共11页Power System Technology

基  金:国家电网有限公司总部科技项目“大规模新能源集中并网地区电压质量治理技术”(4000-202014051A-0-0-00)。

摘  要:针对目前大规模风电汇集系统无功-电压控制中的无功分配问题,根据无功就地平衡原则,给出了无功的均衡分配方式,并定义了风电场的无功不均衡以及无功环流,提出了无功不均衡的评价指标;然后分别探讨了现有电压指令计算方式和无功控制周期不同对无功均衡性的影响;提出了考虑无功均衡性的风电场群无功-电压协调优化模型,并给出相应求解方法;基于所提优化模型,对现有风电场无功电压控制流程进行改进完善,纳入了对无功不均衡度的约束,在无功不均衡度过大时采用恒无功控制对无功进行调整。最后基于华北地区某风电场汇集系统,验证了所提策略可以在保证汇集母线电压控制精度的前提下,减小无功不均衡,抑制无功环流。Aiming at the problem of reactive power distribution in the current reactive power-voltage control in the large-scale wind power collection system, this paper first defines the reactive power imbalance and the reactive power circulation of the wind farm, and gives the evaluation index of the reactive power imbalance. Then, the influence of the existing voltage command calculation methods and the different reactive power control cycles on the reactive power balance is discussed. A secondary voltage control optimization model that considers reactive power imbalance and voltage deviation of Convergence Node is proposed, and the corresponding solution is given. Based on this optimization model, the existing wind farm reactive power and voltage control process is improved and the reactive power imbalance constraint is considered in the process. When the index of the reactive power imbalance is too large, the constant reactive power control is used to adjust the reactive power. Finally,based on a wind farm cluster in the north of Hebei province, it is verified that the proposed strategy is able to reduce the reactive power imbalance and suppress the reactive power circulation under the premise of ensuring the accuracy of the Convergence Node voltage control.

关 键 词:无功-电压控制 无功不均衡 无功环流 优化模型 改进控制流程 

分 类 号:TM73[电气工程—电力系统及自动化]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象