检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:姚明月 曾靖山 郑超 康凯 宋华 周术元 李海龙 白书培 韩浩 YAO Mingyue;ZENG Jingshan;ZHENG Chao;KANG Kai;SONG Hua;ZHOU Shuyuan;LI Hailong;BAI Shupei;HAN Hao(School of Light Industry Science and Engineering,South China University of Technology,Guangzhou 510640,China;State Key Laboratory of National Biological Chemical Protection,Beijing 100191,China)
机构地区:[1]华南理工大学轻工科学与工程学院,广州510640 [2]国民核生化灾害防护国家重点实验室,北京100191
出 处:《环境工程》2022年第10期126-133,共8页Environmental Engineering
基 金:国家自然科学基金项目“疏水性多孔有机骨架制备及其吸附净化化学毒剂模拟剂研究”(21701186)。
摘 要:电热再生是一种效率高、通用性强、能耗低的活性炭材料再生方式,备受挥发性有机化合物治理、室内空气净化及化学防护领域的关注。以活性炭纤维网装填吸附床为研究对象,系统研究了通电电压、吹扫气流比速以及床层吸水率对吸附床电热行为的影响。结果表明:以50 V电压为干燥床层输入1 W·h电能,床层温度可升至144.6℃,与20 V通电电压相比,温度提升了63.8℃;增大吹扫气流比速可降低床层电热过程结束时的温度,并延长通电加热的时间;吸水床层在电热期间出现升温平台,在通电电压为40 V、吹扫气流比速为0.08 L/(min·cm^(2))条件下,根据吸水率的不同,升温平台最长可持续30 min。此外,通电电压和吹扫气流均能影响升温平台对应的温度和持续时间。Electrothermal regeneration is a kind of activated carbon material regeneration method with a short treating time,strong versatility and low energy consumption,and it has attracted much attention in the field of volatile organic compounds treatment,indoor air purification and chemical protection.In this paper,we used activated carbon fiber mesh to fill the adsorption bed,and systematically studied the effects of energizing voltage,specific velocity of purge gas,and bed water adsorption on the electrothermal behavior of the adsorption bed.The results showed that:setting the energizing voltage to 50 V and inputting 1 W·h electrical energy for the drying bed,the bed could rise to 144.6 ℃,which was 63.8 ℃ higher than that at 20 V.Increasing the specific velocity of purge gas reduced the temperature at the end of the electrothermal process and prolong the heating time.There was a temperature rise platform in the water adsorption bed during electric heating.Under the conditions of a voltage of 40 V and a specific speed of purge gas flow of 0.08 L/(min·cm^(2)),the heating platform could last up to 30 minutes according to different water adsorption rates.In addition,the energizing voltage and purge gas could affect the temperature and duration of the heating platform.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.20.239.211