摘  要:针对部分生产及设计单位对消防设施的设置依据和位置存在较大困惑,部分原油处理站场未设置火灾自动报警系统、消防设施仅有就地手动控制功能现象,重点分析了火灾报警及消防联动系统的结构及工作原理,遵循相关规范,以某油田联合站为例,探讨了火灾报警系统设计、消防系统设计及火灾报警及消防联动功能的实现,提高站场火灾应急处置能力。Aiming at the phenomenon that there are larger bewilderments for the setting basis and position in some manufacture and design companies, some crude oil processing stations are not equipped with automatic fire alarm system and the fire-fighting facilities only have local manual control function, the structure and working principle of fire alarming and fire-fighting joint control system are analyzed with emphasis. According to relative specification, taking one oil-field united station as the example, the design of fire alarm system and fire-fighting system, and the realization of the functions of fire alarming and fire-fighting joint control are discussed. The emergency disposal of fire in the station is improved.