作 者:谢菁 叶勇[1,2] 刘阳[1,2] 明皓 任彧 XIE Jing;YE Yong;LIU Yang;MING Hao;REN Yu(College of Civil Engineering,Huaqiao University,Xiamen 361021,China;Key Laboratory for Structural Engineering and Disaster Prevention of Fujian Province,Huaqiao University,Xiamen 361021,China;Fujian Construction Engineering Group Co.,Ltd,Fuzhou 350001,China)
机构地区:[1]华侨大学土木工程学院,福建厦门361021 [2]华侨大学福建省结构工程与防灾重点实验室,福建厦门361021 [3]福建建工集团有限责任公司,福建福州350001
出 处:《建筑结构学报》2023年第2期27-36,共10页Journal of Building Structures
基 金:国家自然科学基金项目(51878304,51808234);福建省自然科学基金杰出青年项目(2020J06020);福建省科技重大专项(2019HZ07011)。
摘 要:为研究内填料石钢管混凝土(SCFST)中长柱的轴压性能,对12根内填料石钢管混凝土中长柱进行单调轴压试验,研究内填料石尺寸、钢管壁厚和长细比对SCFST中长柱受力性能的影响。试验结果表明:内置料石提高了SCFST中长柱的承载力,且增幅随料石尺寸的增大而提高,最大增幅达87%;内填料石尺寸相同时,SCFST中长柱承载力随钢管壁厚的增大近似呈线性增长;随着长细比的增大,SCFST中长柱破坏形态逐渐从轴压破坏转变为压弯破坏,承载力逐渐降低。根据试验结果,对GB 50396—2014中CFST柱相关设计模型用于预测SCFST中长柱承载力的可行性进行评估,预测结果与试验结果误差为-18%~24%,不能较好预测SCFST中长柱的承载力。To further study the axial compressive performance of stone prism and concrete-filled steel tubular(SCFST) slender columns, a total of 12 slender column specimens were tested under axial compression. The main test parameters were the dimension of infilled stone prism, the wall thickness of steel tube and the slenderness ratio. The test results indicate that the infilled stone prism increases the ultimate strength of the slender composite column. The axial compressive strength of SCFST columns tend to increase with the increase of the stone-prism dimension, and the maximum strength increase was 87%. With the same stone-prism dimension, the axial compressive strength of SCFST columns showed a linear increasing trend as the wall thickness of steel tube increases. With the increase of slenderness ratio, the failure modes of SCFST columns shifted from strength failure to instability failure, and the axial compressive strength decrease consequently. Based on the test results, the feasibility of using the available design code GB 50396—2014 for CFST members to predict the axial compressive strength of SCFST slender columns was evaluated, the error between the predicted values and the experimental results is-18-24%, which cannot redict the ultimate strength of the SCFST slender columns precisely.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.140.254.100