检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:姜洋 王勖冲 王萌 满海龙 Jiang Yang;Wang Xuchong;Wang Meng;Man Hailong(POWERCHINA Jilin Electric Power Engineering Co.,Ltd.,Changchun,China)
机构地区:[1]中国电建集团吉林省电力勘测设计院有限公司,吉林长春
出 处:《科学技术创新》2023年第4期57-60,共4页Scientific and Technological Innovation
摘 要:基于《消防应急照明和疏散指示系统技术指标》《发电厂和变电站照明设计技术规定》等规范,以500 kV变电站配置实例来讨论变电站消防设计中备用照明的供电方式和配置容量的原则,主要讨论火灾时仍需工作的消防照明、火灾时仍需工作的生产照明。提出具有可供参考的设计方案。Based on the technical standards such as "Technical standard for fire emergency lighting and evacuate indicating system " and "Technical code for design of lighting of power plants and substations",discuss the power supply mode and configuration capacity principle of standby lighting in the fire protection design of the substation with the configuration example of 500 kV substation, mainly discusses the fire protection lighting that still needs to work in case of fire and the production lighting that still needs to work in case of fire. Propose reference scheme for design.
分 类 号:TU113.668[建筑科学—建筑理论] TM63[电气工程—电力系统及自动化]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.90