作 者:张军[1,2] 周凯 李治阳 聂永山[3] ZHANG Jun;ZHOU Kai;LI Zhiyang;NIE Yongshan(College of Architectural and Environmental Engineering,Wuxi City College of Vocational Technology,Wuxi 214153,China;Wuxi Research Center for Environmental Science and Engineering,Wuxi 214153,China;Beijing Municipal Research Institute of Environmental Protection,Beijing 100037,China)
机构地区:[1]无锡城市职业技术学院建筑与环境工程学院,江苏无锡214153 [2]无锡环境科学与工程研究中心,江苏无锡214153 [3]北京市环境保护科学研究院,北京100037
出 处:《工业水处理》2023年第2期161-166,共6页Industrial Water Treatment
基 金:江苏高校“青蓝工程”资助项目;无锡城市职业技术学院“青蓝工程”资助项目。
摘 要:某餐厨垃圾压榨液废水处理项目设计处理规模为240 m^(3)/d。为确保项目废水达标排放,在分析餐厨垃圾压榨液原水水质的基础上,进行了工艺预选论证与组合工艺设计。设计采用隔油沉渣+混凝沉淀+气浮为前期预处理单元,利用VABR厌氧+二级A/O+MBR系统作为生化处理单元,最后利用臭氧催化氧化+混凝沉淀并联合活性炭过滤塔作为深度处理单元。项目跟踪监测运行结果表明,工艺出水COD为80~120 mg/L、BOD_(5)<5 mg/L、NH_(3)-N为22~36 mg/L、TN为32~57 mg/L、TP<5 mg/L、动植物油<5 mg/L。组合工艺整体出水水质稳定,符合污水接管排放要求。压榨液处理的直接成本约为32.83元/m3。该项目具有整体投资少、占地省、处理成本低等优点,可为同类项目的建设提供参考。The design treatment scale of a kitchen waste pressing liquid wastewater treatment project was 240 m3/d.In order to ensure the discharge of wastewater up to the standard,based on the analysis of the raw water quality of pressing fluid,the project had carried out process pre-selection demonstration and combined process design.Oil separation sediment,coagulation sedimentation and air flotation were adopted as the preliminary pretreatment unit.VABR anaerobic and secondary A/O and MBR system were used as biochemical treatment unit.Finally,ozone cata⁃lytic oxidation,coagulation sedimentation and activated carbon filter tower were used as the advanced treatment unit.The tracking monitoring operation results of the project showed that the effluent COD was 80-120 mg/L,BOD_(5) was less than 5 mg/L,NH_(3)-N was 22-36 mg/L,TN was 32-57 mg/L,TP was less than 5 mg/L and animal and veg⁃etable oils were less than 5 mg/L,respectively.The overall effluent quality of the combined process was stable and met the requirements of sewage discharge.The direct operation cost of pressing fluid treatment was about 32.83 yuan/m3.The project had the advantages of less overall investment,less land occupation and low treatment cost,which could provide reference for the similar projects.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:18.191.37.17