Double pigtail catheter reduction for seriously displaced intravenous infusion port catheter:A case report  被引量:1

在线阅读下载全文

作  者:Yu Liu Duan-Ming Du 

机构地区:[1]Department of Interventional Therapy,Shenzhen Second People’s Hospital,The First Affiliated Hospital of Shenzhen University,Shenzhen 518035,Guangdong Province,China

出  处:《World Journal of Clinical Cases》2023年第4期883-887,共5页世界临床病例杂志

基  金:Supported by Shenzhen Key Medical Discipline Construction Fund,No.SZXK052。

摘  要:BACKGROUND Implanted intravenous infusion port(TIAP)is mainly used for patients who need central venous infusion and poor peripheral vascular conditions.With the advantages of easy to carry,long maintenance cycle,few complications and excellent quality of life,it has been widely used in the fields of malignant tumor chemotherapy,parenteral nutrition support and repeated blood collection.Implanted intravenous infusion port(IVAP)dislocation can have significant complications if not recognised and reinstated immediately.CASE SUMMARY A 24-year-old man was treated with adjuvant chemotherapy for osteosarcoma.Severe displacement of IVAP catheter was found by chest X-ray examination.The IVAP cannot be used normally.Therefore,we conducted an emergency procedure to reset the catheter through double pigtail catheters,the operation was successful and the infusion port was restored.CONCLUSION When IVAP catheter displacement cannot be reset by conventional techniques,two pigtail catheters can be successfully used instead.

关 键 词:CATHETER Displaced catheter IMPLANTABLE Implanted intravenous infusion port Pigtail catheter Case report 

分 类 号:R445[医药卫生—影像医学与核医学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象