检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:李谦 张义 王森 张波[4] LI Qian;ZHANG Yi;WANG Sen;ZHANG Bo(Guangdong Key Laboratory of Electric Power Equipment Reliability,Electric Power Research Institute of Guangdong Power Grid Corporation,Guangzhou 510080,China;Electric Power Research Institute of China Southern Power Grid Co.Ltd.,Guangzhou 510663,China;Electric Power Research Institute of Shaanxi Power Grid Corporation,Xi'an 710000,China;Tsinghua University,Beijing 100084,China)
机构地区:[1]广东省电力装备可靠性企业重点实验室广东电网有限责任公司电力科学研究院,广州510080 [2]南方电网科学研究院,广州510663 [3]国网陕西省电力公司电力科学研究院,西安710100 [4]清华大学,北京100081
出 处:《电瓷避雷器》2023年第1期148-156,共9页Insulators and Surge Arresters
摘 要:输电线路接地故障的短路电流回流将在源端变电站接地网产生较高的暂态电位差和内部转移电位差,可能引发接地系统问题,对接地网均压、电气完整性和绝缘提出较高的要求。本文以接地运行变压器引发转移电位差而导致油色谱装置输油管放电烧蚀漏油、变电站内部参考电位引发转移电位差而导致火花放电草地起火,以及暂态电位升高风险点引发接地系统故障等典型事件为案例,对暂态地电位升不均匀性分布进行计算分析,指出线路故障期间的源端变电站网内暂态转移电位差可达到数千伏的水平,具备触发火花放电或绝缘击穿的条件,给站内绝缘薄弱点带来运行风险,提出对站内转移电位危害的高风险点加强与主接地网连接的电气导通性和做好隔离的有针对性的防范措施。The short-circuit current backflow of the the transmission line grounding fault will generate high transient potential difference and internal transfer potential difference in the grounding grid of the source substation,which may cause problems in the grounding system,and put forward higher requirements for the voltage equalization,electrical integrity and insulation of the grounding grid.In this paper,the typical accidents are discussed,such as that the grounded operation transformer causes the transfer potential difference,which leads to the discharge,ablation and oil leakage of the oil pipeline of the oil chromatography unit;the transfer potential difference caused by the internal reference potential of the substation,which leads to the spark discharge and the grass to catch fire;and the transient potential rise risk point causes the grounding system fault.The non-uniform distribution of transient ground potential rise is calculated and analyzed.And it is pointed out that the transient transfer potential difference in the source substation network during the line fault may reach to thousand of volts,which has the conditions to trigger spark discharge or insulation breakdown,bringing operation risks to the weak points of insulation in the station.The preventive measures are put forward to strengthen the electrical continuity and isolation of the high-risk points of transfer potential hazards in the station.
关 键 词:变电站 线路接地故障 接地网 暂态地电位升 转移电位
分 类 号:TM862[电气工程—高电压与绝缘技术] TM63
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:18.116.67.226