1000 MW汽轮发电机组低压旁路阀内漏分析与处理  

Analysis and Treatment of Internal Leakage of Low Pressure By-pass Valve of 1000 MW Steam Turbine Generating Set

在线阅读下载全文

作  者:姜建强 王勇 张成振 JIANG Jianqiang;WANG Yong;ZHANG Chengzhen(National Energy Group Shouguang Power Generation Co.,Ltd.,Weifang 262714,China)

机构地区:[1]国能寿光发电有限责任公司,山东潍坊262714

出  处:《山东电力高等专科学校学报》2023年第1期61-64,共4页Journal of Shandong Electric Power College

摘  要:针对某电厂1000 MW汽轮发电机组低压旁路阀多次出现内漏的问题,介绍了低压旁路阀内漏的危害,分析了低压旁路阀内漏的原因,提出了具体的处理措施。该厂在计划检修期间,对阀门组件进行升级改造,机组启动后阀后管道温度长期保持在30℃左右,内漏问题得到解决。In allusion to the internal leakage problem of low pressure by-pass valve of 1 000 MW steam turbine generating set in a power plant,the harm of the internal leakage of low pressure by-pass valve is introduced,the causes of the internal leakage of low pressure by-pass valve are analyzed,and the specific treatment measures are put forward. During the planned overhaul period,the plant upgraded the valve components,the pipeline temperature behind the valve remained at about 30 ℃ for a long time after the generating set is started,and the internal leakage problem is solved.

关 键 词:低压旁路阀 内漏 优化设计 

分 类 号:TK264[动力工程及工程热物理—动力机械及工程]

 