摘  要:结合“安全生产专项整治三年行动计划”,提出并应用“七步推进法”隐患排查治理法,对其公司所辖配电自动化机房开展消防安全隐患排查,针对排查出的隐患采用安装七氟丙烷自动灭火系统进行专项治理并取得了实效,最后提出了日常运行维护相关注意事项。Combined with three-year special rectification action plan for safety production, the "sevenstep promotion method" is proposed and used as the approach for hidden hazard investigation concerning the fire protection safety troubleshooting of the belonging automatic power distribution rooms, based on which special rectification actions are carried out on the safety hazards discovered by use of heptfluoride propane automatic fire extinguishing system with verified effects, and several precautions corresponding to daily maintenance are finally put forward.