某600 MW亚临界燃煤锅炉[火用]分析  

Exergy Analysis of a 600 MW Subcritical Coal-fired Boiler

在线阅读下载全文

作  者:焦开明 Jiao Kaiming(Inner Mongolia Datang International Tuoketuo Power Generation Co.,Ltd.,Hohhot 010200,China)

机构地区:[1]内蒙古大唐国际托克托发电有限责任公司,呼和浩特010200

出  处:《发电设备》2023年第2期94-97,共4页Power Equipment

摘  要:基于热量分析法和[火用]分析法,分析研究某600 MW亚临界燃煤锅炉的给水温度、排烟温度对[火用]效率的影响。结果表明:降低排烟温度或提高给水温度,有利于提高锅炉[火用]效率,可为类似燃煤锅炉节能诊断提供参考。For a 600 MW subcritical coal-fired boiler, based on the thermal analysis method and the exergy analysis method, the influence of the feedwater temperature and the exhaust gas temperature on the exergy efficiency was analyzed and researched. Results show that, the exergy efficiency of the boiler can be improved by reducing the exhaust gas temperature or increasing the feedwater temperature. This may serve as a reference for energy-saving diagnosis of similar coal-fired boilers.

关 键 词:锅炉 热效率 [火用]效率 给水温度 排烟温度 

分 类 号:TK212[动力工程及工程热物理—动力机械及工程]

 